background image

DS-220R User’s Guide  

 

12 

Calibration 

The DS-220R is calibrated at the factory to provide high accuracy.  While 
recalibration should seldom, if ever, be necessary, recalibration is performed easily 
without sending the product to the manufacturer for service.  A known calibration 
weight (in kilograms) is required to recalibrate the scale, and can be any value 
between 5 kg and 100 kg. 25 kg is recommend.  Best accuracy is obtained by using 
the largest weight available (i.e. a 50 kg calibration weight will provide better 
calibration accuracy than a 5 kg calibration weight).  In addition, it is necessary to 
know the weight to within 2 grams. 

To recalibrate the DS-220R, perform the following steps: 

1.  Place the DS-220R weighing platform on a firm, level surface. 

2.  Turn the power to the DS-220R off. 

3.  Remove all objects from the platform. 

4.  While holding 

, press and release 

.  The DS-220R will turn on, and after a 

few seconds the display will show 

SET CAL

 and 

25.000 kg

5.  Using 

 or 

  adjust the displayed value (in 2g increments) so that it is equal 

to the weight of the reference calibration weight.  Use the 

 key to adjust in 1 

kg increments. 

6.  Press 

.  A number representing the weight of the unloaded platform will 

appear on the display.  Press 

 to lock in this value. The display will read zero.  

7.  Apply the calibration weight to the platform.  A number representing the applied 

reference weight will appear on the display. Allow at least 10 seconds for this 
number to stabilize. 

8.  Press 

.  The DS-220R is now recalibrated to the reference weight. 

9.  Refer to the Quick Start section above for setting the desired Units and 

Resolution. 

Содержание DS-220R

Страница 1: ...DS 220R Digital Charging Scale User s Guide...

Страница 2: ......

Страница 3: ...matic refrigerant charging for A C systems Features Large high visibility LCD display Measures Weight in kgs and lbs Built in memory remembers all previous settings Refrigerant Tank Capacity Indicator...

Страница 4: ...ser s Guide 2 Parts Diagram LCD Display Easel Extended Keypad Weighing Platform Coiled Cord Mounting Hooks Speaker Grill Easel Retracted Optical Port for CM 500 Battery Cover Storage Dock Control Box...

Страница 5: ...Floating Negative Indicator Indicates weight removed from platform G Battery Level Indicator H Fast Adjustment Indicator I Set Mode Indicator J Tank Capacity Mode Indicator K Run Mode Indicator L Hold...

Страница 6: ...displayed units Press to select low medium or high display resolution Press to zero out current reading on display Use to adjust various settings and programming values For faster adjustments Used in...

Страница 7: ...ION section Basic Weighing Operation 1 If using a container to hold the objects being measured place it empty on the center of the platform 2 Press to zero out the scale The display will read zero 3 P...

Страница 8: ...20R 1 If extended restore the easel to the retracted position 2 Wrap the coiled cord counter clockwise around the weighing platform 3 Push the control box firmly into the storage dock of the weighing...

Страница 9: ...o MEDIUM resolution suitable for most purposes The resolution can be changed to LOW MEDIUM or HIGH by repeated pressing on the keypad The table 1 illustrates the displayed resolution for each units mo...

Страница 10: ...or replace objects bins or containers on the platform 4 Wait 5 seconds for the new load to stabilize 5 Press The HOLD indicator will turn off Measurements will continue from where they left off prior...

Страница 11: ...RUN again press the previous set point will be restored followed by again The display will be zeroed when the program restarts You may program the SET mode without starting the RUN mode by pressing a...

Страница 12: ...sh in the Alternate Numeric Display indicating that the weight of a full container must be registered 5 Apply a full container or a load representing the weight of a full container on the platform Wai...

Страница 13: ...g down press The SET TANK indicator will turn on and OFF will show on the display This indicates that the Tank Capacity Mode is currently off 2 Turn the Tank Capacity Mode on by pressing The display w...

Страница 14: ...220R weighing platform on a firm level surface 2 Turn the power to the DS 220R off 3 Remove all objects from the platform 4 While holding press and release The DS 220R will turn on and after a few se...

Страница 15: ...ection above for setting the desired Units and Resolution NOTE When calibrating or restoring the factory calibration or must be held while pressing and releasing Otherwise the calibration or calibrati...

Страница 16: ...d via a utility hose Open the cylinder valve and purge air from the hose 5 Program the desired refrigerant charge weight as described in the Programming section Activate the program by pressing 6 Open...

Страница 17: ...IED WARRANTIES OF MERCHANTABILITY AND FITTNESS FOR A PARTICULAR PURPOSE Core Enterprises Inc shall not be liable for any incidental or consequential damages caused by the breach of any express implied...

Страница 18: ...DS 220R User s Guide 16 Notes...

Страница 19: ...DS 220R User s Guide 17 Notes...

Страница 20: ...AccuTools is a trademark of Core Enterprises Inc P N 10154R Rev B 3650 Coral Ridge Drive Suite 101 Coral Springs FL 33065 Ph 954 227 0781 Fax 954 227 1094 www accutools com...

Отзывы: