background image

MP5032-2104

XLR8 HEATED PLATEN

26

LIMITED WARRANTY

One Year– Parts and Labor

U.S. & Canada Only

AccuTemp Products, Inc. (AccuTemp) warrants that your AccuTemp equipment will be free of 
defects in material and workmanship under normal use for a period of twelve (12) months 
from installation or fifteen (15) months from date of shipment from AccuTemp, whichever date 
first occurs (the Warranty Period). Registration of AccuTemp equipment is required at the 
time of installation. Damage to AccuTemp equipment that occurs during shipment must be 
reported to the carrier, and is not covered under this warranty. The reporting of any damage 
during shipment is the sole responsibility of the commercial purchaser/user of such AccuTemp 
equipment.

AccuTemp provides an active service department, which should be contacted and advised 
of service issues, regardless of the warranty period. During the warranty period, AccuTemp 
must  be contacted  for  warranty  repairs  and agrees to repair or replace, at its option, 
F.O.B.  factory, any  part  which  proves  to  be  defective  due  to  defects  in  material  or 
workmanship,  provided  the equipment has not been altered in any way and has been properly 
installed, maintained, and operated in accordance with the instructions in the AccuTemp 
Owners Manual. During the warranty period, AccuTemp also agrees to pay for any factory 
authorized equipment service agency (within the continental United States and Canada) for 
reasonable labor required to repair or replace, at our option,  F.O.B.   factory,  any  part  which  
proves  to  be  defective  due  to  defects  in  materials  or workmanship, provided the service 
agency has received advance approval from AccuTemp factory service to perform the repair or 
replacement. This warranty includes travel time not to exceed two hours and mileage not to 
exceed 50 miles (100 miles round trip), but does not include post start-up assistance or training, 
tightening of loose fittings or external electrical connections, minor adjustments, maintenance, 
or cleaning. AccuTemp will not reimburse the expense of labor required to replace parts after 
the expiration of the warranty period.

Proper installation is the responsibility of the dealer, owner-user, or installing contractor and 
is not covered by this warranty. Improper installation can affect your warranty. Installation 
is the responsibility of the Dealer, Owner/User or the Installation Contractor. See the 
Installation section of the Owners Manual. While AccuTemp products are built to comply 
with applicable standards for manufacturers, including Underwriters Laboratories (UL) and 
National Sanitation Foundation (NSF), it is the responsibility of the owner and the installer to 
comply with any applicable local codes that may exist.

AccuTemp makes no other warranties or guarantees, whether expressed or implied, including 
any warranties of performance, merchantability, or fitness for any particular purpose. 
AccuTemp liability on any claim of any kind, including negligence, with respect to the 
goods and services covered hereunder, shall in no case exceed the price of the goods 
and services, or parts thereof, which gives rise to the claim. In no event shall AccuTemp 
be liable for special, incidental, or consequential damages, or damages in the nature of 
penalties.

This constitutes the entire warranty, which supersedes and excludes all other 

warranties, whether written, oral, or implied.

Содержание XLR81B-00 Series

Страница 1: ...MP5032 2104 AccuTemp Products INC 11919 John Adams Drive New Haven IN 46774 www accutemp net XLR8 HEATED PLATEN INSTALL SERVICE AND PARTS Serial Number Model...

Страница 2: ...ty Warnings 2 General Info 3 Installation 4 Operation 7 Planned Maintenance 11 SERVICE Sequence of Operation 12 Troubleshoot Guide 13 Removal Replacement of Parts 16 PARTS 21 Warranty 26 TABLE OF CONT...

Страница 3: ...ially hazardous situation which if unchanged will result in minor or moderate injury NOTE Advises the reader of information or instructions vital to the operation or maintenance of the equipment In th...

Страница 4: ...North Clinton Park Fort Wayne IN 46825 800 210 5907 260 493 0415 Fax 260 493 0318 accutemp net XLR8 Upper Heated Platen Replace with voltage Model XLR8 1B 00 208 1 Amp kW 10 A 2 1 kW 240 1 Amp kW 11...

Страница 5: ...reful inspection of the packaging and the equipment should be completed before acceptance from the transportation company 3 3 XLR8 LIFTING The equipment is heavy enough to require additional manpower...

Страница 6: ...remove the ground prong of the plug The XLR8 has been designed manufactured and tested to meet or exceed the demanding standards of safety set forth by ANSI NFPA 70 To to ensure that this high level...

Страница 7: ...loat locks to hold them in in the new position 6 If the float locks are not retained tighten the four 6 32 nyloc nuts on the studs to prevent them from coming loose or remove the nuts and flat washers...

Страница 8: ...all operators read understand and follow the information contained in this manual including caution warnings operating instructions and safety instructions Never use wet or damp gloves as moisture can...

Страница 9: ...seconds The control is now in Manager Program Mode the icon will light LED1 only will blink and the keypad will be reconfigured as shown in the following table In managers mode the keypad will operate...

Страница 10: ...LED indicator for the selected pre set will blink The LED s indicate which preset is selected LED1 PRESET 1 LED2 PRESET 2 and LED3 PRESET 3 iii Then press the UP or DOWN KEYS to increase or decrease...

Страница 11: ...shipped in its locked setting which keeps the platen cooking surface horizontally level and is designed for the cooking of level products such as burgers Please use caution as temperatures on and arou...

Страница 12: ...rect If the stand has casters check that the wheels are intact and that they are mounted correctly If grease covered clean with a mild detergent and clean water Dry completely Apply a food grade silic...

Страница 13: ...s through the back heater thermostat to a white high temp Y wire harness which connects to the controller circuit board terminal J7 1 then daisy chained to J7 3 and to J7 5 10 When the ON OFF key is p...

Страница 14: ...BREAKER ON CORRECT INTERNAL VOLTAGE INTERNAL FUSE INTACT HEAT ON ERROR CODE TIMER ACTIVATES PRODUCT UNDER COOKED PRODUCT OVER COOKED CORRECT TEMPERATURE YES NO YES YES YES NO NO YES YES YES NO YES NO...

Страница 15: ...nge wire harness from terminal J7 1 4 Ohm across the two white wires removed If open then a lead wire to the bimetal thermostats or a bimetal thermostat is opened Let the heaters cool then retest 5 If...

Страница 16: ...netic proximity switch from the board Set up a multimeter to test for resistance across the two wires leading to the proximity switch 3 Test if the proximity switch closes when the arm is lowered If t...

Страница 17: ...ERMINAL END AS 6 N A T U O TION DATE APPR VISIONS PROTOTYPE 08 25 2020 RRR DEV002214 1 PART NUMBER Revision 3 AT0E 2699 3 E 3 AT0E 2684 2 A02 4 AT0F 1052 23000 G07 4 DEV002324 1 01 2 AT0F 2691 41001 D...

Страница 18: ...mbly 8 With one hand on the handle to prevent the arm assembly from rapidly lifting up remove the heater cover 8 32 X 3 8 Truss head screws doing the ends first then finish in the center of the heater...

Страница 19: ...out the switch 10 Apply a small amount of thermal compound to the bottom of the overtemp switch where it will make contact with the element 11 Reverse procedure to reinstall 12 Use permanent lock tit...

Страница 20: ...e tooth comb included with the kit vertical and draw it along the length of the element in several passes to obtain an even uniform thickness coating across the entire surface After each pass remove e...

Страница 21: ...16 nylock nut 1 standard flat washer and 2 large flat washers and urethane die spring from the threaded shaft 7 To reinstall ensure a large flat washer is on either side of the urethane die spring fo...

Страница 22: ...h Material Comments Unless otherwise specified Dimensions Inches Bends 90 Tolerances Angular 1 2 Place Decimal 02 3 Place Decimal 005 T I R 005 125 Micro Inches GD T Per ANSI Y14 5M INDICATED EDGES MU...

Страница 23: ...2 8 22 4 40 4 1 22 44 44 12 14 15 37 13 17 32 25 32 35 38 33 36 31 20 10 19 18 26 27 24 28 23 30 11 1 50 F G J B Tuesday November 24 2020 11 33 51 AM 11 5 3 9 2 7 D 12 10 8 6 4 1 4 6 8 10 12 7 2 9 3 5...

Страница 24: ...49 8 F 27 STRAIN RELIEF 3 4 HUB CABLE RANGE 500 625 1 AT0A 2788 50 U06 26 POWER CABLE ASSY 2 MCMASTER 97633A230 00 25 RING RETAINING 5 8 SHAFT 1 AT0E 1049 9 24 STRAIN RELIEF 3 8 HUB CABLE RANGE 312 43...

Страница 25: ...08 25 20 Date Name AccuTemp Products Inc 8415 N Clinton Park Fort Wayne IN 46825 DEV002214 Size Drawing No Rev Title D Sheet 1 of 1 Scale 1 3 ECN Unless otherwise specified Dimensions Inches Bends 90...

Страница 26: ...imensions Inches Bends 90 Tolerances Angular 1 2 Place Decimal 02 3 Place Decimal 005 T I R 005 125 Micro Inches GD T Per ANSI Y14 5M INDICATED EDGES MUST BE SOFTENED NEAR SIDE FAR SIDE BOTH SIDES 6 9...

Страница 27: ...provided the service agency has received advance approval from AccuTemp factory service to perform the repair or replacement This warranty includes travel time not to exceed two hours and mileage not...

Страница 28: ...AccuTemp product may be covered by one or more US patents See www accutempip net...