Chapter 1: The LC1400 System
1-8
Addressing Supervisor Alarms
A Supervisor Alarm occurs when the
performance of the system has been altered
due to tampering or inadvertent acts such as
cut wires, antenna damage or interference, etc.
When a Supervisor Alarm occurs:
1) Go to the alarm location.
2) Look for visible damage to the Accutech
equipment.
3) Check for and remove any objects that
may be causing interference near the
zone equipment—including metal carts,
monitors or other medical equipment,
as well as personnel using wireless
communication devices.
4) If you locate and correct the cause,
the Supervisor alarm will cease; if not,
call your service technician for further
assistance.
Addressing Tamper Alarms
A Tamper alarm occurs when the LS2400T
cover is removed and its tamper detect
infrared sensor is triggered.
If the unit is in alarm (red light on Keypad) and
one or more of the following conditions has
been met, then it is possible that someone has
tampered with the cover of the unit by trying
to remove it.
• No monitored residents have been found to
be in the area while the door was opened
• The door is closed
• Power to the unit has been verified
• You have reset the zone with the Keypad
Contact maintenance or your local service
provider or call 1-800-356-2671 for 24-hour
telephone technical support.
Escorting
Disclaimer:
The following instructions are
intended only as recommendations. Each
facility should review these recommendations
and make changes as necessary to meet their
own unique security requirements.
While escorting tags through zones, be wary
of tailgating. Tailgating is the practice of tags
lingering near a monitored zone (usually an
exit point) until an authorized escort passes
through the zone and the tag immediately
follows behind.
To prevent tailgating, be aware of all traffic
near a monitored zone. Once you are through
the monitored zone, wait until the escort timer
has timed out and the unit has reactivated.
To escort tags through a monitored zone, use
the following instructions:
1) Enter a valid code into the zone’s keypad.
This will invoke the keypad’s Escort
function. The keypad’s Escort function
will allow the tag to pass through the
monitored zone for the pre-set Escort
time. The duration of the Escort function
is adjustable from 0 to 98 seconds
(factory set at 15 seconds).
2) Escort the tag through the zone.
Important:
For slower moving residents,
you may need to invoke the Escort
function again; however, if this is the
case, an alarm may sound. Take into
consideration the Escort time duration
at that zone. If the door is used to escort
slow-moving residents often, consider
extending the Escort time or using a
wheelchair to escort residents.
3) Once you are through the zone, prevent
tailgating by waiting until the Escort
time has timed-out (the green LED will
extinguish) before you proceed.
Содержание LC1400
Страница 2: ......
Страница 9: ......
Страница 10: ......
Страница 11: ...Chapter 1 The LC1400 System...
Страница 30: ......
Страница 31: ...Chapter 2 The LC1400T...
Страница 43: ......
Страница 44: ......
Страница 45: ...Parts 77L016 SB 77L017 WW 77L018 LT 77L018 W LT W 772015 IDTAD 700020 B TTS Chapter 3 Tags IDTAD TTS...
Страница 66: ......
Страница 67: ...Part 650514 Chapter 4 The Magnetic Switch...
Страница 72: ......