background image

 

Accurate Technology Inc. 

Page 3 of 20 

 

FCC NOTICE 

 

This equipment has been tested and found to comply with the limits for a class 

B  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.    These  limits  are 

designed  to  provide  reasonable  protection  against  harmful  interference  in  a 

residential installation.  This equipment generates, uses and can radiate radio 

frequency  energy  and  if  not  installed  and  used  in  accordance  with  the 

instructions,  may  cause  harmful  interference  to  radio  communications.  

However,  there is no guarantee that  interference  will not occur  in  a  particular 

installation.    If  this  equipment  does  cause  harmful  interference  to  radio  or 

television reception, which can be determined by turning the equipment off and 

on,  the  user  is  encouraged  to  correct  the  interference  by  one  or  more  of  the 

following measures: 

 

  Reorient or relocate the receiving antenna. 

  Increase the separation between the equipment and the receiver. 

  Connect  the  equipment  to  an  outlet  on  a  circuit  different  from  that  to 

which the receiver is connected. 

  Consult  the  dealer  or  an  experienced  radio/television  technician  for 

help. 

 
Operation  with  non-approved  equipment  is  likely  to  result  in  interference  to 

radio and TV reception.  The user is cautioned that changes and modifications 

made to the equipment without the approval of the manufacturer could void the 

user’s authority to operate this equipment. 

Содержание ProScale

Страница 1: ...Firmware version 1 0 and greater User Manual ProScale RF Receiver...

Страница 2: ...lectronic or otherwise without the expressed written permission of Accurate Technology Inc Firmware Version 1 000 P N 800 1340 001 Revision A Copyright 2004 2005 Accurate Technology Inc All rights res...

Страница 3: ...is equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to correct the interference by one or m...

Страница 4: ...ut mode 1 10 Output mode 2 10 Output mode 3 11 Output mode 4 11 Output mode 5 12 DELETING A PREVIOUS MEASUREMENT RECORD 13 SECTION 4 OPERATION 14 COMMAND FORMAT EXAMPLES 14 System ID 14 Output Mode 14...

Страница 5: ...l data in standard ASCII text format and may be configured for various output formats In addition the receiver will support standard baud rates from 2400 to 115200 bits per second The following is a l...

Страница 6: ...ion with computers This can include upper and lower case letters numbers and punctuation Field A field is an individual data element such as position units or other information Delimiter A character t...

Страница 7: ...rear of the receiver Connect the female socket end to the PC serial port Note If using a newer laptop computer there may be no RS 232 port installed on your PC In this case it is recommended that you...

Страница 8: ...minal program for the serial port being used to communicate with the receiver The following are the default port settings of the receiver 9600 baud 8 data bits No parity 1 stop bit Flow Control None A...

Страница 9: ...D s within radio range from being received The default is 0 O Output mode Formats the record text for the desired data content See Output Modes on page 9 for more information The default is mode 3 pos...

Страница 10: ...mode when interfacing with TigerStop In the case of output mode 0 an ASCII position is provided followed by the programmed terminator carriage return or carriage return and line feed CR or CR LF In t...

Страница 11: ...7 where 0 is a very weak signal and 7 is a very strong signal This can be used for verifying the quality of signal reception from a particular transmitter location The status information is used in c...

Страница 12: ...line format For detailed information regarding the ProRF communication format review the document entitled ProRF System Definition and Communications Protocol Architecture available from Accurate Tech...

Страница 13: ...0 Always 0 9 1 Always 1 10 1 Always 1 11 1 1 inches 0 mm 12 space if positive if negative 13 hundreds digit 14 tens digit 15 8 ones digit 16 decimal point 17 5 tenths digit 18 3 hundredths digit 19 7...

Страница 14: ...view System ID To display the current system ID type in s ENTER The receiver responds with System Factory Default 0 To change the system ID to 21 type S21 ENTER The receiver responds with System now 2...

Страница 15: ...th Echo mode off Record Start Marker To display the current record start marker status from default type in m ENTER The receiver responds with Marker mode Factory Default off To change the record star...

Страница 16: ...ctive 1 second after the command is issued to allow the change message to be sent at the old baud rate Available baud rates are 2400 4800 9600 19200 38400 57600 115200 Firmware Version ID To display t...

Страница 17: ...designed to operate as a slave device In this mode a standard serial cable is used to connect the unit to a PC for normal operation In some cases it may be required to use the receiver as a master dev...

Страница 18: ...ProScale RF Receiver User Manual Page 18 of 20 This page intentionally left blank...

Страница 19: ...N Fill out for your records and FAX to Accurate Technology 1 828 654 8824 or Register on line at http www proscale com registration htm Name E Mail Company Address Address City State Region Zip Postal...

Страница 20: ...etcher NC 28732 USA 800 233 0580 828 654 7920 Fax 828 654 8824 www proscale com customerservice accurate technology com This manual is available at www proscale com Please return your Product Registra...