ProPanel-HD (FW4), Revised August 2020
Page 19 of 24
Programming Mode
Many features of the readout can be customized (plus additional tools can be
enabled) using the programming menu. For information and videos about using
the programming menu, go to
Parameter
number
What it does
Default value
Pr1
Sets the DATUM key value.
0.000
Pr2
0 = default reading direction
1 = reversed reading direction
0
Pr3
0 = +, - and DATUM keys are operative.
1 = These keys are disabled (LOCK).
0
Pr4
The resolution for decimal readings.
3
Pr5
Motion needed to wake up the readout.
0.004 inches
Pr6
Do fractions round up or down?
0 (round down)
Pr7
Resolution of 4
th
decimal place (inches)
1 (.0005” resolution)
Pr11
Controls available units modes.
0 (All units)
Pr12
Auto-off timer (in minutes)
15
Pr13
Linear multiplier
1.00000
Pr14
Encoder compatibility
1 (Absolute scale)
Pr15
LCD contrast adjustment
27
Pr16
Final linear multiplier
1.00000
Pr22
ABS/INC key operation
0 (2 seconds)
Pr23
Supplemental keys enabled?
3 (All enabled)
Pr24
Monitor/hold, Go/NoGo features
0 (Disabled)
Pr25
Go/NoGo values to save
0 (None)
Pr26
Drift Monitor tolerance
.01 inches
Pr27
Limits modes used
0 (Not used)
Pr28
Lower limit value
0.000
Pr29
Upper limit value
5.000 inches
Pr30
Offset additions to use
0 (None)
Pr31
First offset value
0.5000 inches
Pr32
Second offset value
2.0000 inches
Pr33
Third offset value
3.0000 inches
Pr34
Fourth offset value
3.0000 inches
Pr35
External input operation mapping #1
0 (No function)
Pr36
External input operation mapping #2
0 (No function)
Pr37
Polarity for Output functions
0 (Normally open)
Pr38
Output Function used
0 (None)
Pr39 *
Turn on non-linear compensation
0 (Disabled)
Pr40 *
Non-linear correction step value
5.000 inches
Pr41 *
Temperature compensation on/off
0 (Off)
Pr44 *
Coefficient used for temperature
150