![ACCURAT Opti 10 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/accurat/opti-10/opti-10_operating-manual_456500051.webp)
Fault Codes
Error Code
Power-
LED
Fully
Charged-
LED
Fault-
LED
Cause
Solution
Reversed
Polarity /
Output Short
—
—
☼
Short circuit or
reverse connection
of the clips
Check clips are not
touching each other
OR Check the clips are
correctly connected to
the battery.
Non Battery
Link
—
—
☼
Non battery link
Please choose the
right battery type for
connection.
Faulty Battery
●
—
☼
Bulk charging
has timed out
and stopped after
24 hours.
Battery is faulty and
may need to be
replaced.
Over Voltage
—
—
☼
The 12V battery
voltage is above
17.5V.
The 24V battery
voltage is above
35V.
Disconnect the
charger and check
the battery voltage.
This charger is
suitable for 12V or
24V Batteries only.
Overheating
—
—
●
Internal
temperature
is above
65 °C +/-5 °C
Turn off charger and
allow to cool.
There are error codes that may be displayed. These will be displayed
in the following way:
●
= permanently lit,
☼
= flashes, — = off
51