![ACCURAT Opti 10 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/accurat/opti-10/opti-10_operating-manual_456500043.webp)
Specifications
Opti
5 (24 V)
Opti
10 (24 V)
Charger Type
7 stage automatic
Input Voltage
220 – 240 V~, 50/60 Hz
Input Power
296 W
547 W
Output Voltage
24 V DC
24 V DC
Output Current
5 A
10 A
Min. Star Voltage
4 V
4 V
Current Fuse Rating
250 V AC, T3,15 A
250 V AC, T3,15 A
Charge Control
Desulphation
Pulse charge up to 11 V
Soft Start
Half the rated set current up to 12V
Bulk
5 A up to 28,8 V
10 A up to 28,8 V
Absorption
Constant voltage until
current drops to 0,75 A
Constant voltage until
current drops to 1,5 A
Battery Test
Monitors voltage for 90 seconds
Recondition
Constant current (0,75 A) for 4
hours limited to 32 V
Constant current (1,5 A) for 4
hours limited to 32 V
Float
27,6 V – also with pulse feature
Efficiency
approx. 85 %
Overheating Protection
65 °C +/- 5 °C
Cooling Fan
Automatic temperature controlled
Ambient Temperature
-20 °C to +50 °C, output power is reduced automatically at high
temperatures
Over Voltage Protection
The 12V charger will automaticallyp rotection if the
voltage is higher than 35 V
Battery Range
Deep Cycle
35 – 100 Ah
70 – 200 Ah
Battery Types
Most types of lead acid batteries including Calcium, GEL and AGM
Dimensions (LxBxH)
215 x 115 x 62 mm
215 x 115 x 62 mm
Weight
1,2 kg
1,23 kg
43