background image

 

12 

   

 

This symbol is used inside system. 

Identifies the point where the safety ground of the system is fastened to 

the chassis. 

 

Do not open. This is for factory only. 

 

Alternating current 

 

Direct current 

 

Date of manufacture 

 

Manufacturer 

 

Non-ionizing radiation 

 

CE mark 

 

 

Serial No. 

 

Authorized representative in the European community. 

 

Keep dry 

 

For indoor use only 

 

RoHS2 

 

Содержание BC720

Страница 1: ......

Страница 2: ...THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93 42 EEC SELVAS Healthcare Inc 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do 38470 Republic of Korea TEL 82 53 856...

Страница 3: ...and its function 24 INSTALLATION 27 1 Power Supply 27 2 Peripheral Device Installation 28 1 Connecting Computer 28 2 Connecting Printer 28 3 Connecting Blood Pressure Monitor 29 4 Connecting ultrason...

Страница 4: ...AGE MAINTENANCE 61 ERROR REPAIR 62 1 Kinds of Error Repair 62 2 Error Occurrence Repair 64 AFTER SERVICE 65 1 AFTTER SERVICE 65 2 PACKING AND TRANSPORT 65 SPECIFICATION 66 WARRANTY 68 INSTRUCTIONS FOR...

Страница 5: ...ORD DEFINITIONS To ensure safe operation and long term performance stability it is essential that you fully understand the functions operating and maintenance instructions by reading this manual befor...

Страница 6: ...arning During measurement of the body composition a microcurrent of 180 A flows through the body Individuals who have any kind of implanted active medical devices such as pacemakers should not use thi...

Страница 7: ...ents for storage Where the ambient temperature falls below 25 C or exceeds 70 C Where the atmospheric pressure falls below 70kPa 700mbar or exceeds 106kPa 1060mbar Where the humidity is over 93 non co...

Страница 8: ...d the patient simultaneously Prohibition The unit has previously been adjusted in the factory for optimum performance Do not attempt to adjust switches or any other things except those specified in th...

Страница 9: ...mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT Note Consult a physician or a trained health professional for interpretation of measurement results Note In case of patients...

Страница 10: ...for system s non compliance with specifications or responsibility for any damage or injury This manual is made for informational purposes and this manual and product are not meant to be a substitute...

Страница 11: ...our safety Degree of protection against electric shock TYPE BF Please observe operating instructions General warning sign General prohibition sign General mandatory action sign Caution Waste Electrica...

Страница 12: ...und of the system is fastened to the chassis Do not open This is for factory only Alternating current Direct current Date of manufacture Manufacturer Non ionizing radiation CE mark Serial No Authorize...

Страница 13: ...used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The ACCUNIQ BC720 uses RF energy only for its internal function Therefore its R...

Страница 14: ...ality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be t...

Страница 15: ...est IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 Vrms 150 kHz to 80 MHz 3 V m 80 MHz to 2 5 GHz 3 Vrms 3 V m Portab...

Страница 16: ...as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the el...

Страница 17: ...ency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz d 1 2 80 MHz to 900 MHz d 1 2 900 MHz to 2 5 GHz d 1 2 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3...

Страница 18: ...ed with weight invisible or visible obese Strictly speaking obesity is the state that body fat occupies considerably high ratio to weight 3 Necessity of Body Composition Analysis Body Composition Anal...

Страница 19: ...in case of abdominal obesity W H R is the ratio of waist to hip circumference and has relation to one s figure 6 Segmental Analysis This device analyzes soft lean mass body fat mass total body water a...

Страница 20: ...USB Cable Data management program Bolts 5mm L wrench Body Cover Bluetooth Model or specification of accessories can be changed according to market supply and demand TERMS OF EACH PART AND FUNCTION Us...

Страница 21: ...xercise plan etc If the device is connected to blood pressure monitor it also indicates the measurer s blood pressure 3 A4 result sheet for segmental parts and children It shows the segmental results...

Страница 22: ...ement LCD monitor attached to the column leads the user to measure height in correct way When using SM103 Install it in a place with stable temperature Do not install it at the location facing the hea...

Страница 23: ...3 3 Appearance of the device The front and back of ACCUNIQ BC720 looks as below It consists of Display Operation Part Body Part Base Part Front Part Rear Part Display Operation Part Body Part Base Par...

Страница 24: ...tal Display panel as touch screen It is easy to input data 2 Body Part Holders of Handle electrode Handle electrodes are rested on the holder when they are not used Start button Press Start button wit...

Страница 25: ...uld step them in bare feet Horizontal level A level to regulate horizontality of the analyzer Body cover It covers the joint between the base and body parts 4 Wheels support the analyzer Regulate the...

Страница 26: ...are Inc HEIGHT A port to connect ultrasonic height meter Adapter port Connecting the adapter Power switch It can be used to turn on off the power Caution A window in the rear part of this analyzer is...

Страница 27: ...peripheral devices are connected each other the order of turning of the devices should start from the device to keep the functions and safe of the device 3 This device should be only powered through t...

Страница 28: ...ote 1 If use USB port the cable should be connected to the computer port 2 When use computer port USB driver should be installed at first For more information please refer to the manual CD of software...

Страница 29: ...this case 2 The professional consulting software optionally provides various printouts In case of using the software the pre printed result sheet is not used 3 Refer to user s manual for installation...

Страница 30: ...assembly push the lower board of the ultrasonic height meter into the bottom back of ACCUNIQ BC720 Fix the left and right parts firmly using hinge and screw Connect RS 232 cable to the HEIGHT port pla...

Страница 31: ...Menu in SYSTEM SETUP Menu items are displayed The function of each icon is as follows 1 DATE TIME 2 VOLUME 3 PRINT 4 PRINT POSITION 5 CLOTHES 6 SCALE OFFSET 7 ABDOMINAL FATNESS 8 DATE TYPE 9 DATABASE...

Страница 32: ...e from SYSTEM SETUP Press CLOSE button on SYSTEM SETUP phase then back to initial view of the analyzer 5 How to move into SYSTEM SETUP Press CLOSE button on the menu view then program is returned to S...

Страница 33: ...t VOLUME on SYSTEM SETUP screen with button and press SET on touch pad Pre set 3 Range 0 9 Adjust volume with button on touch pad Press SET on touch pad to save selected value Return to SYSTEM SETUP s...

Страница 34: ...g button moves print position up or left Every single press moves print position by about 0 2 mm Press SET button on touch pad to save it Return to SYSTEM SETUP screen by pressing CLOSE button on touc...

Страница 35: ...ed in body composition analysis Select SCALE OFFSET on SYSTEM SETUP screen and press SET on touch pad Pre set 0 0 kg Range 9 9 9 9 kg Set the value by pressing on touch pad Every single press changes...

Страница 36: ...r of saved data and the backup progress Please wait for backup to complete RESTORE If you want to load the data stored in the external memory to the main unit connect the external memory to the back a...

Страница 37: ...f ID function is not activated the user should input basic information before the test starts 2 If FLASH MEMORY is selected the results are saved in flash memory in the machine itself If USB MEMORY is...

Страница 38: ...D Only the child growth curve is not printed in case of 18 or over 18 ADULT No matter what age is set it prints the result sheet for ADULT The child growth percentile is presented on the ADULT result...

Страница 39: ...l analysis are printed together and in case of choosing NO only the result sheet for Body composition analysis is printed HEIGHT METER Adjust the height meter and select the use of height meter Preset...

Страница 40: ...be used on the left upper side of the screen Press ID on the screen and enter an index number and press button Then you can search or see the results and print them 3 Setting a measurement mode Users...

Страница 41: ...easure 3 4 hours after a bath a sauna exercise or activity that sweats a lot Or measure before these actions Avoid drinking alcohol 24 hours before the measurement Wear clothes as light as possible On...

Страница 42: ...ate electrodes are clean Take off the socks or stockings then stand on the plate electrodes Remove sweat or foreign matters on the soles Fairly place the bare feet on the plate electrodes Make sure th...

Страница 43: ...subject has hands or feet that are too small to cover all electrodes sufficiently for measurement please pay attention to touch all electrodes fairly How one touches electrodes will affect the reliabi...

Страница 44: ...old the same posture until the measurement is over Do not speak or move the body until the measurement is completed Do not bend or shake the arms until the measurement is completed The measurement wil...

Страница 45: ...wer is on the initial screen appears as shown in the picture The following message appears To start please measure your weight When the user steps on the scale the measurement starts with a chime bell...

Страница 46: ...nput your age and confirm it Select gender The LCD screen changes as shown in the picture with a chime bell When the user hears the voice guidance Select Male or Female select the gender Note If want...

Страница 47: ...buttons Do not move or speak during measurement Measuring LCD turns to MEASURING view Voice guidance announces Starting measurement don t move or speak please Grab the handle LCD indicates how the ele...

Страница 48: ...ck the measurement data with your mobile device and manage it at will from the server in which it is saved Note 1 Scan the QR code with a QR code reader in a smart mobile device 2 The data saved in th...

Страница 49: ...es on the LCD approximately 5 seconds Measurement starts with message Look at LCD When the measurement completed it displays the result of weight and height on the LCD With chime bell you can start in...

Страница 50: ...ody fat while checking the blood pressure simultaneously The measuring procedure is as follows Connect a Blood Pressure Monitor to the device Connect the device to a computer Turn on the power of BPM...

Страница 51: ...B MEMORY When USB MEMORY is selected measurement data will be stored to USB MEMORY without notification Data can only be saved when USB MEMORY is inserted only at the initial screen of device If USB M...

Страница 52: ...message All data were deleted will appear Press Close to return to initial screen Deleted data can not be restored Note 1 USB memory should be inserted only at the initial screen 2 When there s no dat...

Страница 53: ...Result sheet There are two kinds of result sheet One is for body composition analysis and the other is for segmental assessment For Body composition analysis Users can see the overall body composition...

Страница 54: ...person loses weight by the optimal fitness programs or gains weight the components of the weight will probably change as well as the ratio of these components to one another Body composition table pr...

Страница 55: ...lled voluntary muscle because one can move this muscle voluntarily unlike visceral muscle Skeletal muscle enables people to walk and perform other voluntary activities Mineral Composed of bone and ele...

Страница 56: ...s Abdominal fatness is divided into subcutaneous type and visceral type When it comes to body fat experts say that not only the amount of fat is important but also its distribution If visceral fat are...

Страница 57: ...d in kg unit Prediction of Abdominal Fat It is the graph of V F A If the user doesn t exercise and just keep the current life style the graph indicates how V F A increases and how BMR decreases every...

Страница 58: ...ergy while muscle consumes energy Therefore even if the weight is same between persons the person with more muscle has greater B M R 2 T E E Total Energy Expenditure It is the sum of basal metabolic r...

Страница 59: ...n the blood pressure monitor supplied from SELVAS Healthcare Inc is connected to the device blood pressure can be measured and the result can be printed out Systolic blood pressure diastolic blood pre...

Страница 60: ...r cable plug and fuse that are offered by our company At this time confirm the covering of cable the state of plug connection and other check points RS 232C cable USB port Adapter 12 When pulling out...

Страница 61: ...hing with wrong input of personal data age gender nor with measuring error of weight and impedance try again It can t measure if the P B F is out of range When the same error occurs even after re meas...

Страница 62: ...be entered Can t measure the weight When the subject s weight deviates from the limit Measuring error Moving during the measurement Measure the weight again Don t move or speak during measurement It...

Страница 63: ...e again correctly Try to measure again after cleaning the electrode holders with soft gauze Try again after cleaning the hands and soles Check if foreign materials are between electrodes and measuring...

Страница 64: ...are designated by our company as repairable How to contact our company Write us at SELVAS Healthcare Inc 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do Korea TEL 82 53 856 0993 FAX 82 53...

Страница 65: ...l Segmental lean mass and assessment Segmental fat mass and assessment Segmental ratio of ECW and assessment History Weight SMM Fat mass PBF BMI WHR ECW ratio Body type 20 types Segmental Body water S...

Страница 66: ...594lb Applicable age 1 99 years old Operation ambient Ambient temperature range 5 to 40 C Relative humidity range 15 to 93 non condensing Storage ambient Ambient temperature range 25 to 70 C Relative...

Страница 67: ...e of purchase Within 1 year from the date of purchase Customer Add Name Tel Dealer market Add Name Tel Note When you receive this warranty make sure that the name of the dealer and the month day and y...

Страница 68: ...king and transport 1 Components 2 Unpacking UP mark should be indicated on the top side of the box when you place the Carton box on a surface Remove the strap with a scissor or a knife Make sure not g...

Страница 69: ...he air pack for protecting products Take out the protection air pack and check its components inside 3 Installation More than two workers hold the device and lift it up Take the device out of t he Car...

Страница 70: ...stic package from the Body and scale After connecting the scale harness and the scale PCB stand the body up One person screws 2pcs of M8 bolts in the left and right side of the body using 5mm L wrench...

Страница 71: ...71 4 Assembling the body cover Push the body cover in the arrow direction shown in the picture below and adhere to the scales packing How to adhere Body cover Completely adhered Scale packing...

Страница 72: ...four wheels After adjusting the level connect the provided adapter and power cable and turn on the device If you press the power saving button on the right side of the column as shown in the picture i...

Страница 73: ...check and manage the result data on the exclusive mobile device app via Bluetooth connection Components for Bluetooth Unscrew the bolts 2EA and cable grand 1EA with a driver Keep the separate bolts 2E...

Страница 74: ...the main body connecting cable to the reverse side of the antenna and fix the cable by screwing the bolts in with a driver Connect the unconnected side of the cable to EXTERNAL PORT on the back side o...

Страница 75: ...75 Fix the Bluetooth to the back side of the main body with the provided bracket using a driver The installation is completed by turning on the device Joint of bracket...

Страница 76: ...inimum 2 people to ensure safe operation 1 Components for installing an ultrasonic height meter 2 Assembling the lower body Put the bottom board on the floor and fix the lower body as shown in the pic...

Страница 77: ...be shaken and the other unscrews two fixing bolts from the back cover on the upper body using a driver and separate it A person grasps the lower body not to be shaken and the other lifts up the back...

Страница 78: ...body of the height using the 5mm 6angles wrench While a person takes the top harness of UHM out to the inside of the lower board the other puts a upper body supporter into two halls on the top of lowe...

Страница 79: ...is separately packed apart from the harness of UHM to the port attached to the inside of the lower board of the height meter The connector on the other side of the RS 232C cable will be connected with...

Страница 80: ...er board of UHM and the other two are attached in the reinforcing board of UHM Check the condition after adjusting the level Horizontal bolt Horizontal bolt Normal Abnormal Water Drop Horizontal Meter...

Страница 81: ...de of the device as shown in the picture and then connect the adapter After connecting cables turn on the main body and UHM If a height is less than 120cm measure the height after putting a reflector...

Страница 82: ...er to the arrow direction using a driver and separate the cover Connect the Bluetooth which connected with a cable to the EXTERNAL port on the back side of the device and switch on the Bluetooth Conne...

Страница 83: ...83 Check the location of the bracket hole and stick to the Bluetooth and fix it on the backside of the height meter as shown in the picture Joint of bracket...

Страница 84: ...e to ensure safe operation 1 Components for installing an ankle electrode 2 Installing an ankle electrode Turn off the power of the device and disconnect the power cable before installing an ankle ele...

Страница 85: ...ale by using a driver Check the RS 232C port of the weight scale and ankle electrode Connect the RS 232C port of the ankle electrode to the weight scale as shown in the picture Ankle electrode RS 232C...

Страница 86: ...with one hand and fix it on the scale firmly by using M12 bolt 10mm 6 angle wrench and M4 bolt 3mm 6 angle wrench After that try shaking the ankle electrode to check if the fixation is good or not M4...

Страница 87: ...87 Remove the protective vinyl and double faced sticker inside of the top cover Attached the top cover on the ankle electrode to the arrow direction in the picture...

Страница 88: ...the installation connect the adapter and power cable and turn on the device If you press the power saving button on the right side of the column as shown in the picture it turns to power saving mode P...

Страница 89: ...ce Pass Fail Mechanical Check 1 Keys Smooth operation Pass Fail 2 Recorder Smooth operation with no abnormal sound Pass Fail Mainframe 3 Touch Screen Smooth operation Pass Fail Accessories 1 Power cor...

Страница 90: ...il Mechanical Check 1 Touch Screen Smooth operation Pass Fail Mainframe 2 Recorder Smooth operation with no abnormal sound Pass Fail Accessories 1 Power cord Smooth operation and removal Pass Fail Ele...

Страница 91: ...91 BC720E 20161124 Rev1 1 EUROPEAN REPRESENTATIVE VITAKO Sp z o o ul Stanis awa aryna 7c 02 593 Warszawa POLAND TEL 48 22 400 8000...