16
Parameter
Valori impostabili Valori di default Note
P01
Boiler type selection
0 ÷ 8
0
0 =
instantaneous
1 =
with kettle thermostat
2 =
with kettle temperature probe
3 =
heating only
P02
Gas type selection
0 - 1
0
0 = natural
gas
1 = L
PG
P03
Selection type DHW control
0 - 1
1
0 =
flow switch
1 =
flow meter
P04
Regulation coefficient with external probe
0 ÷ 90
30
P05
Anti Fast Cycles time
0 ÷ 10 min
3
P06
1
DO NOT MODIFY
P07
Ignition Heating ramp
[value 1=10s]
0 ÷ 80
12
P08
Maximum heating power selection
(PREMIX)
P10...100
70%
P09
Selection of maximum DHW power
P10…100
80%
P10
Minimum power selection
0…P09
0%
P11
Minimum setpoint value selection
heating
20...P12
25°C
P12
Selection of the maximum setpoint value
heating
P11…80
80°C
P13
Selection of the maximum value of the DHW setpoint
35 ÷ 67
60°C
P14
Selection of calibration type
0 ÷ 20
0
0 = manu
5 = auto
P15
Boiler power selection
0 ÷ 4
4
0 = 24 kW
1 = 28 kW
2 = 32 kW
3 = 16 kW
4 = 20 kW
P16
Not used
P17
Not used
P18
Not used
P19
Thermostat
(0) /
Flue gas probe
(1)
0 - 1
1
DO NOT MODIFY
P20
Selection of the minimum value of the DHW
35 ÷ 50
35
P21
Low temperature zone selection
0 - 1
0
0 =
High temperature
1 =
Low temperature
P22
Not used
P23
Selection of pump activation time
(min):
cold area
0 ÷ 10
0
P24
Child protection
0 ÷ 1
0
1 =
active protection
P25
Not used
P26
Ram stroke delay selection
(sec)
0 ÷ 3
0
P27
Preheating temperature selection OFF
(°C)
30 ÷ 75
45
P30
Not used
P31
Fan speed selection
(P31 x 25) rpm
80 ÷ 160
140
P32
Fan max speed selection
(P32 x
25) + 2000) rpm
P33...255
170
P33
Fan minimum speed selection
(P33 x 25)
30 ÷ 60
36
P36
Not used
P37
AUX probe
3 ÷ 3
3
DO NOT MODIFY
P38
Antifreeze temperature selection
0…+10
5
P39
Post-circulation heating time selection
0 ÷ 99 sec x 10
120
P40
Ignition delay time selection heating
0 ÷ 60 sec x 5
0
P41
Sanitary modulation selection with flow meter
0 ÷ 1
1
0 =
not active
1 =
active
P42
Select enable / disable preheating function
ACS
0 ÷ 1
0
0 =
disabled
1 =
enabled
P43
DHW activation delay time selection with
solar configuration
0 ÷ 30 sec
0
P44
Selection of pressure sensor type
0 - 1
1
0 =
pressure switch
1 =
trasducer
P45
Anti-legionella function selection (cylinder only)
54, 55 ÷ 80
54
54 =
disabled
55 ÷ 80 =
delivery temperature set