13.3 CLIMATE MANAGEMENT PROCEDURE
PARAMETERS
CF05
ST08
ST03
SD03
SD05
SD07
AR03
AR20
AR21
AR22
AR23
AR25
AR26
AL19
SET POINT FUNCTION
SET-POINT -
Configuration
PB2
SET-POINT
maximum in heat pump
SET-POINT
winter
(
compressor off at external temp. 50 ° C
)
CLIMATE SET POINT FUNCTION
Max dynamic SET-POINT increment in heat pump max variation
Set external air temp. Dynamic SET-POINT in heat pump
Differential external air temperature dynamic SET-POINT in heat pump
BOILER FUNCTION (BOILER)
Frost alarm set
Boiler function (heating control)
SET-POINT outside air for boiler activation (boiler)
Boiler differential (boiler)
Boiler activation delay time (boiler)
SET-POINT external air compressor deactivation
Compressor activation external air differential
PARAMETERS OF ALARMS FUNCTIONS
Probe for antifreeze alarm signaling
VAL
U
E
4 °C
Outside temperature
65,0 °C max
65,0 °C max
-10,0 °C
-5,0 °C
5,0 °C
4,0 °C - 5,0 °C
0 °C
3,0 °C
0,2 °C
1 (minuti)
0,0 °C
0,5 °C
2,0 °C
13.4
INTEGRATION MANAGEMENT PROCEDURE
PARAMETERS
AR09
AR012
AR15
A16
A17
BOILER FUNCTION (BOILER)
SET-POINT - Antifreeze heaters in heat pump
Anti-freeze resistance differential in heat pump
Anti-freeze resistance adjustment in heat pump
Anti-freeze heater temperature control in chiller (integration boiler)
Anti-freeze heater temperature control in Pd (integration boiler)
VALUE
48,0 °C
2,0 °C
1 (on)
0 (
rule yes PB1
)
0 (
rule yes PB1
)