16
User's Manual
Both hard disks are used as
Target HDD in
ARAID.
Hard drives are using different
UDMA modes.
Both hard disks are different in
efficiency.
※ If the hard disk fails during the rebuilding, ARAID M500 will skip the bad sectors and then
complete the rebuild.
※ Do not use the hard disk which has been determined failed by ARAID M500, otherwise it may
lead to system damage.
Upper bay hard disk has bad
sectors (upper bay to lower
bay rebuilding is in process).
Upper bay hard disk failed
(upper bay to lower
bay
rebuilding is completed).
Lower bay hard disk is failed
(lower bay to
upper bay
rebuilding is completed).
Lower bay hard disk has bad
sectors (lower bay to
upper
bay rebuilding is in process).
Insert the designated Primary
HDD
to start the computer.
If starting is
succeed, insert
Secondary HDD.
Restart the computer.
Restart the computer.
After rebuilding, replace
the upper
bay hard disk
immediately.
Replace the upper bay hard
disk.
Replace the lower bay hard
disk.
After rebuilding, replace
the lower
bay hard disk
immediately.
Status
Description
Action