background image

 

2

 

Contents 
 

Title 

 

          

 

        

Page

 

 

Welcome 

 

 

 

 

General warnings 

 

 

 

 
1.

 

Means of delivery 

 

 

2.

 

Safety instructions 

 

 

3.

 

Intended use   

 

 

4.

 

Technical specification 

 

5.

 

Accessories 

 

 

 

6.

 

Electrical specification 

 

7.

 

Assembly 

 

 

 

8.

 

Chair adjustment 

 

 

9.

 

Footplate operation & adjustment 

10 

10.

 

Manual controls 

 

 

11 

11.

 

Electric controls 

 

 

13 

12.

 

Battery operation and charging 

15 

13.

 

Using the castor brakes 

 

15 

14.

 

Functionality check   

 

17 

15.

 

Cleaning & disinfection 

 

17 

16.

 

Troubleshooting 

 

 

17 

17.

 

Storage 

 

 

 

18 

18.

 

Daily inspection 

 

 

18 

19.

 

General maintenance 

 

18 

20.

 

Guarantee 

 

 

 

18 

21.

 

Disposal 

 

 

 

18 

22.

 

EMC Statement 

 

 

19 

23.

 

Table of symbols 

 

 

23 

24.  

Contact details 

 

 

23 

 
 

 

Welcome 

Dear Customer, 
 
Thank you for purchasing an Accora healthcare 
product. We feel sure that this product will 
exceed your expectations. 
This manual is important for understanding how to 
use your new Configura Advance chair; please 
read it before use. If you need further information, 
or require the information in a different format, 
please contact Accora: 
 
Tel: 01223 206100 
Fax: 01223 206120 
E-mail: [email protected] 

 

General 

The Configura Advance chair is classified as a 
Class 1 Medical Device in accordance with the 
Medical Devices Regulation 2002 as amended 
and the Medical Device Regulation 2017/745. 

    

    

 

 

Notice to User 

If a serious incident occurs in relation to this 
medical device, affecting the user or the patient, 
then the user or patient should report the serious 
incident to the medical device manufacturer (or 
distributor) and, in the European Union, the user 
should also report the serious incident to the 
Competent Authority in the member state where 
they are located. 

 

Accora Ltd, 38 Main Street,  
Swords, Co. Dublin, Ireland, K67 E0A2 
T: +353 (0)1 695 0614 
 

Design Policy and Copyright 

® a

nd ™ 

are trademarks belonging to Accora 

Ltd unless otherwise stated. As our policy is one of 
continuous improvement, we reserve the right to 
modify designs without prior notice. © Accora Ltd 
2020. 

 

Before using the Configura Advance chair, 
you must read and understand the instructions 
in this user manual. All actions and handling of 
the chair must be performed in accordance 
with the instructions in this manual. 
Any actions that are inconsistent with the 
manual are performed at your own risk and 
Accora shall not be liable for any injury or 
damage. Please ensure that the manual is 
available to users and operators throughout 

the chair’s service life.

 

Содержание CHAIR-0-SC1-030

Страница 1: ...Configura Advance Chair Instruction Manual IFU SC1 001EN Rev 04 May 2022...

Страница 2: ...ified as a Class 1 Medical Device in accordance with the Medical Devices Regulation 2002 as amended and the Medical Device Regulation 2017 745 Notice to User If a serious incident occurs in relation t...

Страница 3: ...ents may be used otherwise Accora cannot guarantee against any damage that might occur 14 Inappropriate routing of accessory cables e g cushion pump cable could lead to dangerous electrical hazards if...

Страница 4: ...ng homes or convalescent units The Configura Advance chair may also be placed in private homes where there is unlikely to be 24 hour supervision by clinical staff but where the patient or caregiver is...

Страница 5: ...specification Mains electrical system Description Value Supply voltage 100 240VAC Supply frequency 50 60Hz Max supply current 3 9 Amps Degree of protection against liquid ingress IPX4 Degree of protec...

Страница 6: ...and hold in place Align the mounting hole at the bottom of the gas strut Fig 3 Item 2 and the mounting hole at the bottom of the backrest lockout slide Fig 3 Item 3 with the clevis at the back of the...

Страница 7: ...e other side 10 Secure the backrest cushions to the backrest with the Velcro flaps Each cushion is attached to the backrest with the Velcro flap at the top of the cushion The top cushion has a double...

Страница 8: ...djusted from 330mm 13 to 533mm 21 The height is adjusted using two plungers Chair Width adjustment 1 Make sure a patient is not in the chair 2 Make sure the brakes on all 3 locking castors are locked...

Страница 9: ...ir 2 Undo the hand screw and sidepiece locking plunger Figure 8 3 Pull the sidepiece from the chair seat frame undo the screws Figure 15 from the fixing bars Figure 15 4 Locate the fixing bars to the...

Страница 10: ...that the plungers that secure the footplate Fig 18 Items 1 2 are in the closed position Fig 19 2 Take the footplate Fig 21 and insert the two tapered spigots Fig 21 Items 1 2 into the two sockets eith...

Страница 11: ...is used to adjust this angle 3 Manual Forward Tilt The chair can tilt forwards from 7 degrees normal tilt to 10 degrees of forward tilt with lock bolts removal 4 Manual Leg rest The leg rest can be ad...

Страница 12: ...e 3 Release the lever to lock the tilt in space angle Manual Forward Tilt Adjustment This function enables some patients to exit the chair more easily however it must only be used following a risk ass...

Страница 13: ...est lockout slide Fig 29 Item 1 3 Release the backrest lockout slide by lifting the locking lever away from the backrest lockout slide The backrest can now be adjusted using the backrest lever 4 Pull...

Страница 14: ...f the patient 1 Remove the footplate See section 9 2 Make sure the brakes on all 3 locking castors are locked on 3 Ensure it is safe to move the chair into the forward tilt position 4 Press buttons 4...

Страница 15: ...the charging lead is stretched the two sections may come apart from each other Move the chair nearer to the mains socket and reconnect the two sections of the charging lead We recommend that the batte...

Страница 16: ...he lever will flip up 3 Push the chair forward moving slightly from side to side to ensure 4 To unlock the castor swivel press on the top of the green lever to bring it back horizontal Directional loc...

Страница 17: ...o not use detergents that could alter the structure or behaviour of the plastics petrol etc Clean by wiping with a damp cloth Alternatively use Microfibre cleaning cloth without any soap For extreme s...

Страница 18: ...user or another person The following checks must be carried out 1 Does the chair operate as per its intended purpose without unexpected noise or motion 2 Are there any signs of abuse or excessive wear...

Страница 19: ...SPR 11 Group 1 The chair uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions...

Страница 20: ...s to earth 1kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage variations on power sup...

Страница 21: ...nsmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the followi...

Страница 22: ...ance according to frequency of transmitter M 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 1...

Страница 23: ...inst liquid ingress Do not dispose of in household waste Degree of protection against electric shock Class II Double Insulated For indoor use only Medical Device in accordance with EU Medical Device R...

Страница 24: ...24 IFU SC1 001EN REV 04 Accora Barrington Road Orwell Cambridge SG8 5QP United Kingdom T 44 0 1223 206100 info accora care www accora care...