TDR Sensor Models: 

Acclima offers three TDR sensor models: The TDR315H, the TDR310H and the TDR305H.  These all 
incorporate the same technology in waveform generation and capture. They are all designed for 
operation in any soil texture. They differ in waveguide dimensions and optimum application.  

 

TDR315H Description and Installation: 

The TDR315H uses a 15 cm waveguide with a rod spacing of 1.9 cm.  Because of its larger waveguide it 
has the largest measuring volume of the three sensors 

 than being on the order of 100 ml.  It can be 

installed in any orientation but is usually installed by forcing the waveguide rods into the sidewall of a 
trench that has been dug to the desired depth of installation.  This method results in a horizontal 
installation in undisturbed soil.  A special rod guide supplied by Acclima is used to keep the rods parallel 
while forcing them into the trench sidewall.  It can also be installed in the center of a trench and then be 
backfilled. With this method the backfill needs to be compacted to avoid air pockets near the waveguide 
and to prevent the creation of a preferential path for surface water to percolate down to the sensor.  
When the installation is complete the entire soil volume removed to create the trench must be placed 
back into the trench with sufficient compaction that the backfilled trench surface is even with the 
surrounding soil surface. 

TDR315H Optimum Application: 

The TDR315H provides excellent readings in all types of soils and has the advantage of a larger sampling 
volume than the TDR310H and TDR301H.  Because of the higher impedance waveguide and the longer 
waveguide length the waveform is more susceptible to attenuation by soil ions than is the case with the 
TDR310H and TDR305H.  Hence the TDR315H is not recommended for use where the salt content of the 
soil is exceedingly high. For saturated paste extraction electrical conductivity readings in excess of 10 
dS/m the repeatability of the readings may degrade and even fail.  

 

TDR310H Description and Installation: 

The TDR310H uses a 10 cm waveguide with a rod spacing of 1.14 cm.  The round form factor was 

designed to match the diameter of a 1” schedule 40 PVC pipe.  The top shoulder of the sensor can be 

Содержание TDR Series

Страница 1: ...Acclima TDR Sensor User Manual For Sensor Models TDR305H TDR310H TDR315H...

Страница 2: ...the medium though which the wave has passed The fact that propagation time is independent of soil electrical conductivity leads to the fact that the calculated permittivity is also independent of soi...

Страница 3: ...compacted to avoid air pockets near the waveguide and to prevent the creation of a preferential path for surface water to percolate down to the sensor When the installation is complete the entire soil...

Страница 4: ...was developed from the TDR310H as a measurement solution for soils with exceedingly high salt levels It provides credible measurements in soils with saturated paste extraction EC levels up to 20 dS m...

Страница 5: ...nsor is connected to This may require the use of a laptop and special software provided by the data recorder manufacturer Connecting the Sensors to the Data Recorder The wiring diagram for the sensor...

Страница 6: ...If the data recorder does not supply power to the SDI 12 port then use the diagram below for connecting the sensors...

Страница 7: ...ation The sensor ignores unimplemented commands outside those required by the SDI 12 specification There is no response to them Additional Extended Commands that are not enumerated here are incorporat...

Страница 8: ...aborted Data buffer is empty a CR LF aM Fill data buffer with standard measurement a VVV V TT T PP P EEEE CCCC CR LF where VVV V Volumetric water TT T Temperature C PP P Permittivity no units EEEE Bul...

Страница 9: ...Same as above aV Verify Sensor operation This command produces the same result as the aM Command Same data as aM aD1 aD9 No data for these commands al Send Identification aSSVVVVVVPPPPPPcccxx xx a13A...

Страница 10: ...sensor which is then followed by the serial number Making Measurements with the SDI 12 Sensor There are two commands that cause the SDI 12 sensor to take measurements and store them for subsequent re...

Страница 11: ...or and the commands used to retrieve them Data Item Request Command Response Example Units Volumetric Water Content aD0 25 0 Soil Temperature aD0 32 1 C Bulk Relative Permittivity aD0 32 1 Soil Electr...

Страница 12: ...of seconds that are required to take the readings 001 1 second then finished with the number of data items that will be returned with each measurement request 5 Every response from the sensor is termi...

Страница 13: ...uests the five data items exactly in the same manner as with non concurrent readings Data Communication Error Checking So far all Start Measurement commands that we have discussed have requested data...

Страница 14: ...for sensor operation The measure error code indicates that a point was reached in the waveform analysis where an unresolvable mathematical condition was reached This would be due to shorted rods or t...

Страница 15: ...is desired it is necessary to convert the time ordinate to 5ps units or 220 This number is then converted to hexadecimal 220 decimal 0DC hex If the device address is 1 then the following command is s...

Страница 16: ...Reporting Accuracy 0 25 C 0 to 50 C EC Reporting Accuracy 25 S cm 0 to 1 000 S cm BEC 2 5 1 000 S cm to 6 000 S cm BEC Architectural Characteristics Waveguide Length 305H 310H 315H 5 cm 305H 10 cm 310...