www.accessmatic.com
Opening your life
Opening your life
11
Code:
BD1522
Bulldog
1522
Adjusting knob
TORQUE: For motor output force adjustment to ensure safety.
Clockwise rotation to increase; Counter-clockwise rotation to reduce.
TIME: For slow stop width adjustment.
Clockwise rotation to increase; Counter-clockwise rotation to reduce.
Rotate to the minimum to cancel the slow stop function.
Note: The default setting is TORQUE, TIME are the maximum value, and the user can adjust according to the actual require-
ment.
Warning: The motor output force cannot set too large, just to be able to drive the gate.
Dip switch
1. AUTO CLOSING:OFF - No automatic close function; ON - Automatic close function.
2. RX 4 BUTTON: OFF - Single button mode remote control; ON - Three button mode remote control.
3. SBS MODE: OFF - Pedestrian mode; ON - No pedestrian mode.
4. MOT.DIRECTION: OFF - Left installation; ON - Right installation.
Infrared connection
Note: The infrared connection NC or NO will be memorized while Travel Learning.
Infrared photocell function: In the closing process, when infrared ray of the photocell is covered by people or objects during
its detection range, the gate will open immediately for security protection.
The distance between photocell receiver and photocell emitter should be more than 2 meters, otherwise will affect the
induction of the photocell.
The following figure shows the NO infrared connection. If you want to connect to an NC infrared photo, just change to NC
port. Then please learn travel again to Memory the infrared NC connection.
FIG 2