TECH TALK......TROUBLESHOOTING GUIDE

For SmarTouch Digital

ERROR CODES

COLD  Water temperature below 40 F.                                              OH      Water temperature above 108 F.
SESH  Temperature sensor shorted.                                                  SEOP  Temperature sensor open or disconnected
HLer   Overheat condition or overheat sensor disconnected       PSOL  Pressure-switch open with low speed jets ON.
PSOH  Pressure-switch open with high speed jets ON                 PSOC  Pressure-switch open with circulating pump ON

Error code PSOL?  PSOH? PSOC?

EXPLANATION:
No water pressure. Pressure Switch Open. 
-Check if circulation /filtration pump is running. 
-Check for the following symptoms:

PUMP running but no water flow

-Check for possible airlock. Pump is not primed. Check  for a closed gate valve.

PUMP does not run. 
-Is primary pump connected.

Only a trained or qualified technician can perform the following procedure

-Measure, using a voltmeter, INCOMING POWER. 
-240 VOLTS. Across L1 & L2 at Terminal Block ( 240V installations only)
-Check pump power rating. 

Measured voltage  at pump connector MUST match power rating at pump motor label.

-Measure 240 or 120 Volts @ primary pump connector (pump 1) across WHITE and RED for low speed (PSOL) and WHITE
& BLACK for high speed jets.(PSOH)

NO POWER READING AT PUMP CONNECTOR:

Replace PCBoard. Possible burnt fuse or  pump relay circuit defective, provided incoming power is verified at main Terminal
Block. 

POWER O.K.:

Replace pump. 

PUMP runs and there is flow:

- Heater manifold must be plumbed to pump discharge or output side to activate pressure switch. 
-Check Pressure Switch connections at Pressure Switch. 
-Jumper across pressure switch terminals. If error code goes  away check Pressure Switch calibration or P/S is defective.  

Spa will not heat.

Check for error codes ‘OH’  or “HLEr”. If YES then check for the following:
-Good water flow.
-Possible air pocket inside Heater Manifold or an Air Lock

1- Is Heater indicator light ON at spaside control panel?

Yes

Go to next step.

                                                                                                                                                         

2- Is Red indicator light located at equipment enclosure “ON”?

YES

-Burnt element. Replace heater element. 

Page 25

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

TEMPERATURE SETTING . . . . . . . . . . . . . . . . . . . . . . . . 4

SETTING TIME-OF-DAY . . . . . . . . . . . . . . . . . . . . . . . . . . 5

COOL-DOWN TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

USER TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 

SPA-SIDE CONTROL  PANEL 2020 . . . . . . . . . . . . . . . . . 6

SPA-SIDE CONTROL PANEL 1000 . . . . . . . . . . . . . . . . . 7

USER & SYSTEM OPTIONS 
SELF-DIAGNOSTIC ERROR CODES . . . . . . . . . . . . . . . . 8-9

START-UP PROCEDURE. . . . . . . . . . . . . . . . . . . . . . . . . . 10

WATER PRESSURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

FILTER CARTRIDGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . 11

PROGRAMMING (OPTIONAL) . . . . . . . . . . . . . . . . . . . . 12-16

ELECTRICAL INSTRUCTIONS  . . . . . . . . . . . . . . . . . . . . 17-19               

FCC REGULATORY APPROVAL . . . . . . . . . . . . . . . . . . . . 20

WIFI FEATURE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . 21

WIRING DIAGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23

EXPLODED VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26

TA B L E   O F   C O N T E N T S

Содержание SmarTouch Digital

Страница 1: ...H DIGITAL USER MANUAL SmarTouch Digital 1999 Applied Computer Controls SmarTouch SmarTouch Digital are trademarks of Applied Computer Controls This manual may not be copied or reproduced without permi...

Страница 2: ...key 2 Press SET a second time and allow the low speed Jets to run for 2 3 minutes 3 Is temperature reading dropping Does it match the thermometer reading in the spa 4 If YES there is flow restriction...

Страница 3: ...igh speed jets PSOH NO POWER READING AT PUMP CONNECTOR Replace PCBoard Possible burnt fuse or pump relay circuit defective provided incoming power is verified at main Terminal Block POWER O K Replace...

Страница 4: ...your spa for the first time You can familiarize yourself with the rest of the manual at your leisure The more efficient the system is the less energy it uses The concept behind SmarTouch Digital is t...

Страница 5: ...controller will Lock in the new temperature Display current spa temperature IMPORTANT Always turn down the heat before you drain the spa Note Once you select the TEMP or TIME and the SET key is not pr...

Страница 6: ...rts when the heater is turned off and the spa is not in use Upon entering the ECONOMY mode the message ECON is displayed During the Economy mode the spa controller is in stand by three hours at a time...

Страница 7: ...the phone service this may take 1 2 minutes You can also check for the same email on your home computer Enter a USER name 6 characters NO spaces Click Register Bookmark this page and add it to your p...

Страница 8: ...enced radio TV technician for help To satisfy FCC RF Exposure requirements for mobile and base station transmis sion devices a separation distance of 20 cm or more should be maintained be tween the an...

Страница 9: ...operate a 240 volt spa system using a 30 amp breaker Connect 240 volt power to the system as previously described then set it to operate in the low power mode 120 or LOW POWER CONVERSION Press the UP...

Страница 10: ...Error Messages SYSTEM OPTIONS SELF DIAGNOSTIC CODES To Save Changes And Exit Go To Code SEnd To Exit Without Saving Changes Go To Code CAnC ELECTRICAL INSTALLATION INSTRUCTIONS Page 9 Page 18...

Страница 11: ...ccomplished the next step is to fill it and heat the water IMPORTANT It is recommended to perform the following procedure when you drain and refill the spa to protect the heater element Power must be...

Страница 12: ...ing a temperature 2 degrees lower than real temperature increase the number by 4 to get a correct reading The total range of this parameter is 10 degrees Fahrenheit Before doing a calibration Please r...

Страница 13: ...tandard filtration cycles Pressing any other device key will cancel this function PROGRAMMING SmartTouch Digital comes with factory settings Programming the SmartTouch controller is optional The follo...

Страница 14: ...s momentarily the SET DOWN ARROW keys at the same time to access the following options Msg Min Def Max Detail FP1 12 00 Start time of filtration period 1 FP2 12 00 Start time of filtration period 2 FP...

Страница 15: ...s momentarily the SET DOWN ARROW keys at the same time to access the following options Msg Min Def Max Detail FP1 12 00 Start time of filtration period 1 FP2 12 00 Start time of filtration period 2 FP...

Страница 16: ...tandard filtration cycles Pressing any other device key will cancel this function PROGRAMMING SmartTouch Digital comes with factory settings Programming the SmartTouch controller is optional The follo...

Страница 17: ...ing a temperature 2 degrees lower than real temperature increase the number by 4 to get a correct reading The total range of this parameter is 10 degrees Fahrenheit Before doing a calibration Please r...

Страница 18: ...ccomplished the next step is to fill it and heat the water IMPORTANT It is recommended to perform the following procedure when you drain and refill the spa to protect the heater element Power must be...

Страница 19: ...Error Messages SYSTEM OPTIONS SELF DIAGNOSTIC CODES To Save Changes And Exit Go To Code SEnd To Exit Without Saving Changes Go To Code CAnC ELECTRICAL INSTALLATION INSTRUCTIONS Page 9 Page 18...

Страница 20: ...operate a 240 volt spa system using a 30 amp breaker Connect 240 volt power to the system as previously described then set it to operate in the low power mode 120 or LOW POWER CONVERSION Press the UP...

Страница 21: ...enced radio TV technician for help To satisfy FCC RF Exposure requirements for mobile and base station transmis sion devices a separation distance of 20 cm or more should be maintained be tween the an...

Страница 22: ...the phone service this may take 1 2 minutes You can also check for the same email on your home computer Enter a USER name 6 characters NO spaces Click Register Bookmark this page and add it to your p...

Страница 23: ...rts when the heater is turned off and the spa is not in use Upon entering the ECONOMY mode the message ECON is displayed During the Economy mode the spa controller is in stand by three hours at a time...

Страница 24: ...controller will Lock in the new temperature Display current spa temperature IMPORTANT Always turn down the heat before you drain the spa Note Once you select the TEMP or TIME and the SET key is not pr...

Страница 25: ...your spa for the first time You can familiarize yourself with the rest of the manual at your leisure The more efficient the system is the less energy it uses The concept behind SmarTouch Digital is t...

Страница 26: ...igh speed jets PSOH NO POWER READING AT PUMP CONNECTOR Replace PCBoard Possible burnt fuse or pump relay circuit defective provided incoming power is verified at main Terminal Block POWER O K Replace...

Страница 27: ...key 2 Press SET a second time and allow the low speed Jets to run for 2 3 minutes 3 Is temperature reading dropping Does it match the thermometer reading in the spa 4 If YES there is flow restriction...

Страница 28: ...H DIGITAL USER MANUAL SmarTouch Digital 1999 Applied Computer Controls SmarTouch SmarTouch Digital are trademarks of Applied Computer Controls This manual may not be copied or reproduced without permi...

Отзывы: