background image

Getting Started

Placement

Power on/off

Tare weight

Switch mode

Place the scale on a stable and vibration-free surface at a preferably 

horizontal location.

4

[Press]      to turn on the scale.

[Double tap]      to turn off the scale.

[Press]      to tare/zero the weight.

[Press and hold]      to switch modes.

* Please see the “Mode Introduction” section for more details. 

Содержание Lunar AL008

Страница 1: ...Acaia Lunar User Manual FW 1 0 004 AL008 AL009 ...

Страница 2: ...ewing with Flow Rate Indicator Tare Save Mode Introduction Mode 1 Weighing Mode Mode 2 Dual Display Mode Mode 3 Timer Starts with Flow Mode Mode 4 Auto Tare Timer Starts with Flow Mode Mode 5 Auto Tare Auto Start Timer Mode Mode 6 Auto Tare Mode Configuration Appendix Buttons LED indicators Error codes Other Specifications 3 3 3 4 4 4 4 4 5 5 5 5 6 7 8 9 9 9 10 11 12 13 15 20 20 21 22 22 23 Conten...

Страница 3: ...injury or physical damage Thank you for choosing our scale The Acaia Lunar is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience Start by checking your Acaia Lunar box to find the following Note For the best performance place the weight in the center of the weighing pan In the Box Introduction Scale overview Weighing Pan LED Display Power Button ...

Страница 4: ...ce the scale on a stable and vibration free surface at a preferably horizontal location 4 Press to turn on the scale Double tap to turn off the scale Press to tare zero the weight Press and hold to switch modes Please see the Mode Introduction section for more details ...

Страница 5: ... and hold the Power button the LED display will show ACAIA and then changes to SEt Continue holding the Power button until the battery percentage is displayed You can also check the battery level by connecting the scale to Acaia Apps Product Care Information Turn on the Acaia scale Turn on scale Make sure the scale is in weighing mode and the unit is set to gram then tap the T button rapidly Tap T...

Страница 6: ... rate During an espresso brew the Flow Rate Indicator will display the highest peak flow rate of this brew with a single bright LED The Flow Rate Indicator can be activated in the following modes Dual Display Mode Timer Starts with Flow Mode Auto Tare Timer Starts with Flow Mode Auto Tare Auto Start Timer Mode Auto Tare Mode You can also enable markings on the Flow Rate Indicator for easier readin...

Страница 7: ... on the display When brewing is completed and the cup is removed from the scale the display will flash to show the final beverage weight and the average flow rate of the brewing The Flow Rate Indicator will show the average flow rate with a stripe LED and the highest peak flow rate with a single bright LED 7 Brewing with Flow Rate Indicator The highest peak Real flow rate The highest peak flow rat...

Страница 8: ... the scale Press and hold Tare button for 2 seconds when reading is stable The weight is stored as a preset container weight Press and hold Tare button for 0 5 second The scale will display the weight to be deducted You may continue using your scale The net weight is displayed on the scale Action Operation Save Container Weight Press and hold Tare button for 2 seconds Subtract Container Weight Pre...

Страница 9: ... or 0 0005 oz There are two different weighing units in Dual Display Mode gram and ounce In grams the LED display shows 0 00 0 0 In ounces the LED display shows 0 00 0 000 The timer displays from 0 00 to 9 59 and then stops Flow Rate Indicator is supported in this mode Mode Introduction Mode 1 Weighing Mode Mode 2 Dual Display Mode Action Operation Tare Weight Tap Tare button Switch Mode Press and...

Страница 10: ...n When the scale detects the flow of espresso the timer starts The timer will stop when the flow stops Please note The flow detection mode is designed to detect the slow trickle of a shot of espresso The timer may not trigger when attempting to pour from a kettle 10 The timer starts when the flow of espresso is detected When the espresso flow stops the timer stops The droplet icon indicates that y...

Страница 11: ...esigned for baristas who would like to measure the time of the shot starting from the first few drops of espresso When the weight reading is stable the scale will perform the auto tare operation After the scale detects the espresso flow the timer starts automatically The timer will stop automatically when the espresso flow stops 11 The droplet and square icon indicate that you are in Auto Tare Tim...

Страница 12: ...start when a stable weight is placed on the scale Tare Weight Tare function starts when a stable weight is placed on the scale Stop Timer The timer will stop when flow is no longer detected Reset Mode Double tap Tare button Switch Mode Press and hold Power button The scale performs auto tare once a stable weight is detected then the timer starts The timer stops when the espresso flow stops Scale w...

Страница 13: ...e tap Tare button Switch Mode Press and hold Power button The LED display shows 0 0 with the weight in grams The LED display shows 0 000 with the weight in ounces Flow Rate Indicator is supported in this mode Display In this mode the scale will only perform auto tare Put the cup on the scale and auto tare will be performed Pull the shot of espresso as you normally would When the cup is removed fro...

Страница 14: ...nal beverage weight and the average flow rate of the brewing If the scale remains idle for 30 seconds it will reset the timer and perform the tare operation This feature is ideal for streamlining bar workflow The scale automatically resets after the cup has been removed eliminating the need for pressing buttons Note To change this reset time please see Auto Reset Setting in the Configuration secti...

Страница 15: ...tting is SLEEP 3 Please refer to the following table for key operations Configuration Enter Settings Action Operation Next Setting Tap Tare button Previous Setting Tap Power button Enter Setting Press and hold Tare button Toggle Options Tap Tare button Save Option Press and hold Tare button Exit Settings and Return to Modes Tap Power button 15 ...

Страница 16: ...uto Start Timer Mode Setting NOdE_5 On Off On Auto Tare Mode Setting NOdE_6 On Off On Flow Rate Indicator Setting FLorAtE d Default Grad Off Default Average Flow Rate Setting Avg FLo On Off On Weight Stable Indicator Setting StAbLE d On Off Off Auto Reset Setting Auto_rES Off 10 30 30 Pre infusion Time Out Setting PrE_inFu 10 30 60 120 60 Auto Start Sensitivity Setting SEnSE 0 1 0 2 Off Off Weighi...

Страница 17: ...t of time in seconds before the scale enters battery saving mode 3 Tap the Tare button to toggle through the options Default Unit Setting Unit The Default Weighing Unit is set to grams if 9 is selected and ounce if o2 is selected Key Sound Setting bEEP 1 Key Sound setting can also be configured in the Acaia apps 2 Set the Key Sound function to on off to enable disable the beeping sound Weighing Mo...

Страница 18: ...he Weight Stable Indicator on the bottom left of the display lights up when the weight is stable 3 Off Weight Stable Indicator disabled Auto Reset Setting Auto_rES 1 After a cup is removed the timer and weight will automatically reset This setting gives you options on how long to wait for the reset It enables the user to pull successive shots of espresso quickly in the three Auto Start modes 2 The...

Страница 19: ...ivision is 0 1 g 3 d 0 3 g When Zero Tracking is set to be 3 d any initial weight between 0 3 g on the weighing pan will be zeroed out gradually 4 2 d is recommended in general for the Acaia Lunar Zero Range Setting 0 rAnGE 1 The Zero Range Setting determines the range for which the Tare button executes zero operation instead of tare operation 2 When Zero Range is set to 2 the range for zero setti...

Страница 20: ...ton Tare Tap to tare weight Tare and Reset Timer While in Auto Start Modes double tap to zero weight and reset timer Save Subtract Press and hold for 2 seconds to save the container weight Press and hold for 0 5 second to subtract the saved container weight Switch Option While in Settings tap to scroll through sub menus While in sub menus tap to toggle options Confirm While in Settings press and h...

Страница 21: ...ces The indicator also lights up during software update to indicate data transfer Button Pressed Indicator This indicator turns on when a button is pressed Auto Start Timer with Flow Indicator When the scale detects the flow of espresso the timer starts The timer will stop when the flow stops Please note The flow detection mode is designed to detect the flow of espresso The timer may not trigger w...

Страница 22: ...the weight is over the maximum capacity Under load the weight is under the minimum capacity 304 Calibration error Calibration cannot proceed when environmental noises are too strong Please calibrate in a stable environment free of wind vibration etc 904 Password error the default password is 0000 _H2O Water in the Power button H2O_ Water in the Tare button _H2O_ Water in the Power button and Tare ...

Страница 23: ...Limit 2060 g 72 66 oz Power Supply 5 V 500 mA Battery Lithium ion rechargeable 3 7 V 1100 mAh Battery Life 30 40 hours Display 8 digit LED Material Aluminum Acrylic Surface Anodized aluminum coating Black Silver Connectivity Bluetooth 4 0 Warranty 2 Years Inside the Package Acaia Lunar Coffee Scale x 1 Heat Resistant Pad x 1 Non slip Protective Strip x 2 Friction reduction Protective Strip x 2 USB...