ENGLISH
4
Troubleshooting and Diagnostics
Fault
Cause
Remedy
(1)
Digital Input
Configuration fault
(P2...P2)
More than one digital input set for
the same function
Each setting can only be used once
(except settings 0 and )
Only one digital input configured for
MOP function (Up, Down)
One input must be set to MOP Up,
another must be set to MOP Down
PID mode is entered with setpoint
reference and feedback source set
to the same analog signal
Change PID setpoint reference
(P2…P2) or feedback source
(P20).
One of the digital inputs (P2…
P2) is set to 0 and another is
set to …4.
Reconfigure digital inputs
One of the digital inputs (P2…
P2) is set to or 2 and another
is set to or 4.
PID enabled in Vector Torque mode
(P200 = or 2 and P00 = 5)
PID cannot be used in Vector
Torque mode
Remote keypad fault
Remote keypad disconnected
Check remote keypad connections
Low DC Bus Voltage fault Mains voltage too low
Check mains voltage
No Motor ID fault
An attempt was made to start the
drive in Vector or Enhanced V/Hz
mode prior to performing the Motor
Auto-calibration
See P00…P99 for Drive Mode
setup and calibration.
Module communication
fault
Communication failure between
drive and Network Module.
Check module connections
Network Faults
Refer to the module documentation.
for Causes and Remedies.
Output fault:
Transistor fault
Output short circuit
Check motor/motor cable
Acceleration time too short
Increase P04, P25
Severe motor overload, due to:
• Mechanical problem
• Drive/motor too small for
application
• Check machine / system
• Verify drive/motor are proper size
for application
Boost values too high
Decrease P8, P9
Excessive capacitive charging
current of the motor cable
• Use shorter motor cables with
lower charging current
• Use low capacitance motor
cables
• Install reactor between motor and
drive.
Failed output transistor
Contact factory technical support
Output fault: Ground fault Grounded motor phase
Check motor and motor cable
Excessive capacitive charging
current of the motor cable
Use shorter motor cables with lower
charging current
() The drive can only be restarted if the error message has been reset