ENGLISH
motor current rating
P08 =
SMV output rating
x 00
Example:
motor = amps; SMV = 4
amps; P08 = 75%
Note
Do not set above the rated motor current as listed on the motor dataplate.
The motor thermal overload function of the SMV is UL approved as a
motor protection device. If line power is cycled, the motor thermal state
is reset to cold state. Cycling power after an overload fault could result in
significantly reducing the motor life.
Commissioning
Code
Possible Settings
IMPORTANT
No.
Name
Default Selection
Minimum
Frequency
0.0
0.0
{Hz}
P0
• P02, P0 are active for all speed
references
• When using an analog speed
reference, also see P0, P
Maximum
Frequency
0.0
7.5
{Hz}
500
Note
• P0 cannot be set below Minimum Frequency (P02)
• To set P0 above 20 Hz:
- Scroll up to 20 Hz; display shows
(flashing).
- Release
s
button and wait one second
- Press
s
button again to continue increasing P0
WARNING!
Consult motor/machine manufacturer before operating above rated frequency. Overspeeding the
motor/machine may cause damage to equipment and injury to personnel!
Acceleration
Time
20.0
0.0
{s}
00
• P04 = time of frequency change
from 0 Hz to P7 (base frequency)
• P05 = time of frequency change
from P7 to 0 Hz
• For S-ramp accel/decel, adjust P0
Deceleration
Time
20.0
0.0
{s}
00
Example:
if P0 = 20 Hz, P04 = 20.0 s and P7 (base frequency) = 0 Hz;
rate of frequency change from 0 Hz to 20 Hz = 40.0 s
S-Ramp
Integration Time
0.0
0.0
{s}
50.0
• P0 = 0.0: Linear accel/decel ramp
• P0 > 0.0: Adjusts S-ramp curve
for smoother ramp
()
Line Voltage
Selection
*
0 Low (20, 200, 400, 480VAC) * The default setting is for all
drives except when using “reset
50” (Parameter P99, selection 4)
with 480V models. In this case, the
default setting is 0.
High (20, 240, 480, 00VAC)
Motor Overload
00
0
{%}
00
Motor Overload
Type
0
0 Speed Compensation
Ir
100%
60%
30 f
1
0
V008
No Speed Compensation
() Any changes to this parameter will not take effect until the drive is stopped