14
English
3.2. Reset
To reset the camera to its factory settings, first disconnect the power supply. Keep the reset button
pressed and reconnect the power supply to the camera. Continue pressing the reset button for another
15 seconds, then release.
Note
On some cameras, the same button is used for the reset function and the WPS function.
Please refer to the description of the camera.
3.3. WPS
To use the WPS function via the hardware button, connect the camera to the power supply. Wait
approximately one minute until the camera has fully started up. Then, first enable the WPS function on
your receiver (router or recorder). Next, press and hold down the WPS button on the camera for 15
seconds.
Note
On some cameras, the same button is used for the reset function and the WPS function.
Please refer to the description of the camera.
3.4. Alarm input/output
The alarm inputs/outputs are identified as follows on the cameras:
I = Input
O = Output
G = Earth (ground)
The connections are potential-free relays which can be operated with the following maximum
connection voltages:
Max. 120 VAC / 1A
Max. 24 VDC / 1A
Connect your peripherals as follows:
Sensor:
Connect your sensor to the output and earth.
Actuator:
Connect your actuator to the output and earth.
Note for TVIP11561
The earth can be used simultaneously for a sensor (input + earth) and an actuator (output
+ earth).