4.  CONFIGURATION 

 

Make  sure  the  IR-LINK3  wand  is  connected  to  the  PC.  The  interface  must  be 

pointed towards the logger communication window (see Figure below) at a distance of 

about 15 cm. 

 

Infrared interface position 

Click  the 

  button  to  start  the  communication  between  the  logger  and  the 

software; the 

Parameters Configuration

 window is then displayed (as shown in figure 

Configuration  Window,

  below),  showing  the  current  configuration  and  information 

about the logger.  

New  configuration  parameters  defining  the  operation  mode  for  a  new 

application  can  be  entered.  The  user  can  also  obtain  general  information  about  the 

device. The fields of the configuration window are described below:  

 

 

Configuration window 

Содержание TAGTEMP

Страница 1: ...TAGTEMP Data Logger User Manual ABUS TECHNOLOGIES INC...

Страница 2: ...sonal injury or death Therefore comply fully with all Warning and Caution notices Information in this manual is intended only to assist our customers in the efficient operation of our equipment Use of...

Страница 3: ...t II 3 Optic Interface IR Link3 4 Palmtop User 5 5 6 6 7 4 Configuration 1 General information Field 2 Acquisition Field 3 Start Loggings Field 4 Stop Loggings Field 5 Channels Field 6 Palmtop User 8...

Страница 4: ...ograms 2 PRESENTATION 2 1 Technical Parameters Measuring Range Temperature 20 C 70 C Accuracy 0 5 C 25 C 2 C max along the entire measured range Note A measurement error can be fixed using the OFFSET...

Страница 5: ...OG While in stand by not logging or after a series of measurements it flashes once at every four seconds During logging it flashes twice at every four seconds Alarm Indicator AL Warns the user as to a...

Страница 6: ...nding wand IR LINK3 to it Click on the menu Port Clicking on the menu Port all free communication ports available in the computer will be listed usually COM2 once the mouse is frequently connected at...

Страница 7: ...ality of the LogChart II is available for the PDA Palm running the LogChart PalmOS software The program is delivered with the logger The stalled in the Palmtop through a HotSync process data synchroni...

Страница 8: ...start the communication between the logger and the software the Parameters Configuration window is then displayed as shown in figure Configuration Window below showing the current configuration and in...

Страница 9: ...e and time Via Start Stop Button starts and interrupts readings by pressing the Start Stop button in the frontal part of the logger for two seconds See Figure 01 Setpoint acquisitions start when a tem...

Страница 10: ...n the PDA infrared wand to the logger communication window run the LogChart Palm OS software wake up the logger and press Search Device in the Recorded Data screen When the PDA finds the logger the Mo...

Страница 11: ...ption is selected a new box to define the stop logging time is displayed By Start Button Press the Start_Now button from the Monitoring screen to start logging The PDA must be turned towards the logge...

Страница 12: ...within an interval The minimum interval between measurements is 10 second Maximum The value logged will be the maximum value found within ten consecutive measurements taken within an interval The min...

Страница 13: ...g the LogChart II menu During data transference a status bar indicates remaining data to be transferred Data offloading time is proportional to the number of readings logged At the end of data transfe...

Страница 14: ...res and configurations and details about data acquired General Information window 5 1 3 Acquisitions Table Window Data acquired by one or both input channels user defined are displayed in engineering...

Страница 15: ...base and tap on Details Recorded Data Details screen shows information about the data base View Data shows in table format the logged values and the date and time they were performed Press Delete to...

Страница 16: ...ding to local legal rules or returned to ABUSTEK 7 After placing batteries back to the logger make sure the cover is firmly attached to the socket 6 2 Troubleshooting FAULT POSSIBLE CAUSE RESOLUTION L...

Страница 17: ...modify the instrument 9 All connections should be tightened properly 10 Power supply should be constant should not be fluctuating 8 WARRANTY ABUS provides the original purchaser of this instrument a...

Отзывы: