1.  INTRODUCTION 
 

TagTemp 

is a small portable electronic temperature logger. Its internal sensor 

measures  local  environment  temperature  and  logs  such  values  in  an  electronic 

memory. Logged data, or ACQUISITIONS, can be later viewed and analyzed on a PC 

where they can be opened in tabular and graph forms. 

The  logger  is  supplied  with

  LogChart-II 

software,  which  enables  to  set  up  the 

logger operation mode. It is also used for viewing acquisitions. Other parameters such 

as  end  of  measurements,  logging  interval,  etc.,  are  easily  defined  through  the 

LogChart-II

 software. 

Acquisitions can also be exported to be analyzed in other applications, such as 

spreadsheet programs. 

 

2.  PRESENTATION  

 

2.1 Technical Parameters 

 

Measuring Range 

Temperature: -20 °C ~ 70 °C. 

Accuracy 

± 0.5 °C @ 25 °C. 

  ± 2 °C max. along the entire measured range. 

Note: A measurement error can be fixed using the OFFSET parameter in the LOGCHART-II software.

 

Measurement Resolutions 

0.1 °C. 

Memory capacity 

16,000 or 16k logs. 

Measurement Resolution 

:

 1 second min. 

 

  18 hours max. 

Supply 

:

 3.6 V lithium battery (CR2032), built-in. 

Estimated Autonomy 

Higher  than  365  days,  with  weekly  data  reading.  Frequent 

logged data readings may shorten battery life. 

Operating temperature 

From –20°C to 70°C. 

Protection 

IP67 

Material 

Polycarbonate 

Dimensions 

30 x 47 x 0.47 mm 

Logger-PC Data Rate 

40 seconds for 16,000 logs. 

PC Interface 

:

 IR/USB Port or IR/Serial Port 

Log-chart-II software requirement 

:

 Setup Software for Windows 95, 98, NT, 2000 and XP, 

 

  Menus in Portuguese, English, and Spanish. 

 

  Setup, reads and displays data on the screen. 

 

Содержание TAGTEMP

Страница 1: ...TAGTEMP Data Logger User Manual ABUS TECHNOLOGIES INC...

Страница 2: ...sonal injury or death Therefore comply fully with all Warning and Caution notices Information in this manual is intended only to assist our customers in the efficient operation of our equipment Use of...

Страница 3: ...t II 3 Optic Interface IR Link3 4 Palmtop User 5 5 6 6 7 4 Configuration 1 General information Field 2 Acquisition Field 3 Start Loggings Field 4 Stop Loggings Field 5 Channels Field 6 Palmtop User 8...

Страница 4: ...ograms 2 PRESENTATION 2 1 Technical Parameters Measuring Range Temperature 20 C 70 C Accuracy 0 5 C 25 C 2 C max along the entire measured range Note A measurement error can be fixed using the OFFSET...

Страница 5: ...OG While in stand by not logging or after a series of measurements it flashes once at every four seconds During logging it flashes twice at every four seconds Alarm Indicator AL Warns the user as to a...

Страница 6: ...nding wand IR LINK3 to it Click on the menu Port Clicking on the menu Port all free communication ports available in the computer will be listed usually COM2 once the mouse is frequently connected at...

Страница 7: ...ality of the LogChart II is available for the PDA Palm running the LogChart PalmOS software The program is delivered with the logger The stalled in the Palmtop through a HotSync process data synchroni...

Страница 8: ...start the communication between the logger and the software the Parameters Configuration window is then displayed as shown in figure Configuration Window below showing the current configuration and in...

Страница 9: ...e and time Via Start Stop Button starts and interrupts readings by pressing the Start Stop button in the frontal part of the logger for two seconds See Figure 01 Setpoint acquisitions start when a tem...

Страница 10: ...n the PDA infrared wand to the logger communication window run the LogChart Palm OS software wake up the logger and press Search Device in the Recorded Data screen When the PDA finds the logger the Mo...

Страница 11: ...ption is selected a new box to define the stop logging time is displayed By Start Button Press the Start_Now button from the Monitoring screen to start logging The PDA must be turned towards the logge...

Страница 12: ...within an interval The minimum interval between measurements is 10 second Maximum The value logged will be the maximum value found within ten consecutive measurements taken within an interval The min...

Страница 13: ...g the LogChart II menu During data transference a status bar indicates remaining data to be transferred Data offloading time is proportional to the number of readings logged At the end of data transfe...

Страница 14: ...res and configurations and details about data acquired General Information window 5 1 3 Acquisitions Table Window Data acquired by one or both input channels user defined are displayed in engineering...

Страница 15: ...base and tap on Details Recorded Data Details screen shows information about the data base View Data shows in table format the logged values and the date and time they were performed Press Delete to...

Страница 16: ...ding to local legal rules or returned to ABUSTEK 7 After placing batteries back to the logger make sure the cover is firmly attached to the socket 6 2 Troubleshooting FAULT POSSIBLE CAUSE RESOLUTION L...

Страница 17: ...modify the instrument 9 All connections should be tightened properly 10 Power supply should be constant should not be fluctuating 8 WARRANTY ABUS provides the original purchaser of this instrument a...

Отзывы: