13
German
3.3. Overview configuration parameters
Z-Wave products can be used directly after inclusion in the network. However, configuration settings
can be used to adapt the behaviour of the device even better to the requirements of the application and
to activate additional functions.
Para-
meter
Byte
size
Function
Default
value
Description
1
1
Switch type
(switch 1)
1
Setting for the type of switch 1.
0 = push button
1 = switch
(Hexadecimal: 0x00 - 0x01)
2
1
Switch type
(switch 2)
1
Setting for the type of switch 2.
0 = push button
1 = switch
(Hexadecimal: 0x00 - 0x01)
3
4
Automatic switch-off
time
(relay 1)
0
Switches relay 1 off automatically after the set
time.
A value of 0 deactivates the automatic switch-
off.
Adjustable from 0 - 32767 in seconds
(Hexadecimal: 0x00 - 0xA8C0)
4
4
Automatic switch-off
time
(relay 2)
0
Switches relay 2 off automatically after the set
time.
A value of 0 deactivates the automatic switch-
off.
Adjustable from 0 - 32767 in seconds
(Hexadecimal: 0x00 - 0xA8C0)
5
1
Device status after
power failure
(relay 1)
1
Setting which device status should be available
after a power failure.
0 = Status "Off
1 = state before the power failure
(Hexadecimal: 0x00 - 0x01)
6
1
Device status after
power failure
(relay 2)
1
Setting which device status should be available
after a power failure.
0 = Status "Off
1 = state before the power failure
(Hexadecimal: 0x00 - 0x01)
The default value of parameter 1 and 2 was "0" (push button) in the initial firmware
version 1.00. This has been changed to "1" (switch) in the new firmware version 1.03.