14
Note: Only alarm tones are emitted in stand-alone battery
operation, regardless of the jumper setting.
“FORCE LOW VOL”: When this jumper is attached, the alarm
tones of the internal siren are emitted at low volume.
Technical data
Environment class
II
Security level
2 (EN50131-1)
Protection class
IP 54
Operating temperature -10 °C to +50 °C
Humidity
75% relative humidity
Dimensions
135 x 225 x 55 mm (WxHxD)
Weight
420 g (without batteries)
Power supply
Nominal 4.5 V or 12 V DC
Power consumption
55±5% mA (standby)
600 mA (alarm)
Frequency
868.6625 MHz
Signals
Internal piezo signaller
(max. 90 dB(A) @ 1 m)
Tamper monitoring
No
Subject to alterations and errors.
This device fulfils the requirements of the European Parliament
and Board EC directive 1999/5/EC of March 9, 1999 regarding
wireless systems and telecommunication transmitters and the
mutual recognition of their conformity.
The declaration of conformity can be ordered from:
ABUS Security-Center GmbH & Co. KG
Linker Kreuthweg 5
D-86444 Affing
Germany