background image

7/10 - Safety instructions and user guide for the automatic pool cover

This document is the property of AS POOL - NextPool group and cannot be reproduced or communicated without our authorisation.

7

3

 For the OPEN range, remove the cover or casing 

or PVC cap on the motor side. Disconnect wires 

1, 2, 3, and 4 of the motor cable in order to slide 

it completely towards the shaft and remove the 

unlocking ring. 

4

 For the BANC, remove the top cover and unscrew 

the butterfly screw from the housing inside the 

BANC Solar. Disconnect wires 1, 2, 3, and 4 of the 

motor cable in order to slide it completely towards 

the shaft and remove the unlocking ring. 

 For the IMM'Box and the DIVER with the motor 

in a dry pit: remove the key between the shaft and 

the motor casing or remove the motor.

6

 For the IMMAX, IMMEO, DIVER with axial motor: 

in the motor connection box located close to the 

pool,  disconnect  the  limit  switch  wires  and  the 

power wires from the motor cable in order to slide 

the  motor  cable  completely  towards  the  roller 

shaft. Remove the pin blocker to access and lift the 

unlocking pin.

7

 Manually accompany the unrolling of the cover, 

making sure that the motor cable does not jam.

8

 Lock the safety mechanisms.

When commissioning the roller, a new adjustment 

of the motor end of run stops will be needed.

9

  "Waste  Electric  and  Electronic  Equipment" 

(WEEE) is the subject of specific collection. It should 

not be disposed of with your unsorted household 

waste.

5. Maintenance advice

In the event of a malfunction or a repair preventing 

the closure and the securing of the pool, take all 

necessary measures to prevent the access to the pool 

of children under 5 years old.

• 

AS POOL only distributes its technical products via 

a  network  of  pool  professionals  which  carries 

out  the  installation  and  follow-up  depending 

on the specificities of the pool. AS POOL does not 

communicate directly with pool owners. 

• 

Have the automatic cover serviced by a swimming 

pool  professional  (we  recommend  your  swimming 

pool installer whose details are on the cover of this 

manual), who will be able to contact our technical 

assistance department. All spare parts must be original 

spare parts in order to maintain our guarantee and the 

cover’s compliance with the standard.

• 

Each time it is commissioned, the cover should be 

inspected  to  identify  deteriorations  that  may 

compromise its correct operation. A professional will 

diagnose whether some slats need to be replaced.

• 

Check that the upkeep advice is applied and that the 

user carries out his checks regularly. Otherwise go over 

them item by item.

• 

Check that the coupling nuts are tightened, that the 

stop ring and all the screws are present on the axis.

• 

Check  that  the  electric  connections  are  tight  and 

operate correctly. Make sure there is no humidity or 

oxidation on the cover's electric contacts (terminals in 

the box, box connections, contacts of the key switch).

• 

Check the condition and the ageing of the locking 

mechanisms and the bungee cords used to retain the 

PVC slats. Check that the straps are tight on the axis.

• 

Check the correct operation of the filtering system, the 

overflow and the water level regulator.

• 

Carry out several rolling and unrolling tests to make 

sure the cover is operational and especially to check 

that the end of run stops are correctly placed.

• 

When the system does not respond, your installer can 

secure the pool by uncoupling the cover roller (except 

for the ZITA model) and manually unrolling the cover 

onto the pool before locking the safety mechanisms 

on the pool cover. In this situation the pool cannot be 

used until the cover is repaired.

• 

Handling  the  uncoupling  of  the  roller  mechanism 

should be read thoroughly before operation, with the 

installation instructions.

1

 Switch off the box.

 Block the roller rotation while keeping the slats 

rolled around it.

Содержание NEXTPOOL OPEN SURF SYSTEM

Страница 1: ...ease read carefully and keep available for later use 01 2022 Version AE 12 205 6EN 01 2022 ABOVE WATER SLATTED SAFETY COVER OPEN SURF System OPEN SURF System S l a t t ed cover s sta n da r d Complian...

Страница 2: ...OL s experience in manufacturing automatic slatted covers since 1995 It will allow users to make the best use of this product which should give compete satisfaction Compliant with the highest requirem...

Страница 3: ...N SURF 2 solar 12 3 10 Final overall dimensions of the OPEN SURF2 slatted cover 13 3 11 Final overall dimensions of the RAISED OPEN SURF 13 4 Electric connections 4 1 Cabled model 14 4 2 Stand alone a...

Страница 4: ...g and in watertight and accessible boxes located outside of volume 0 of the swimming pool as per the NF C 15 100 standard 1 1 5 Cable exit Determine the cable output position once the rails have been...

Страница 5: ...on the pool liner at the level of the edge opposite the cable exit 1 3 3 Measure a precise length A of 1 m less than the length of the pool and make a mark 2 at the end of A on the pool liner 1 3 4 O...

Страница 6: ...weighs 295 kg and measures 4 6 x 0 6 x 0 8 h 2 1 3 For a 5 x 10 pool the container weighs 395 Kg and measures 5 6 x 0 6 x 0 8 h Fig 5 0 8 m x 0 6 m W 4 2 4 7 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 X 4 6...

Страница 7: ...cut to embed the rail on the bearing block side 25 x 45 mm 45 80 25 Spacing between rails pool 700 mm approx Minimum width cut to embed the rail on the motor side 25 x 80 mm Fig 8 3 3 Assembling the...

Страница 8: ...rail so that it is parallel to the pool Fig 13 Fig 14 Pre drill all the other holes keeping the OPEN SURF close to the hole to be drilled in order to maintain a constant gap between the rails Fig 14...

Страница 9: ...ls bring the power supply cable to the stand Fig 18 Fig 19 Power supply stand Mark the 4 holes using the plate 6 and drill using a 12 mm bit Fit the threaded rods 5 using chemical sealer The rods must...

Страница 10: ...from the edge of the rail The length of the bar must be adjusted from the end of the rail and finish 9 cm from the sides of the coping Carry out tests to check that the cover opens over the pool elec...

Страница 11: ...urf 1 covers Using an Allen wrench unscrew the TRHC M6 x 16 screw lift then remove the cover from the stand Fig 27 Fig 28 3 7 2 Removing Surf 2 covers Using an Allen wrench unscrew the 4 lateral TRHC...

Страница 12: ...12 13 14 15 X 290 300 310 320 330 340 350 360 370 380 390 400 X 3 9 Removing the solar panel OPEN SURF 2 solar Dismantle the motor cover see 3 6 to access the connectors Fig 30 Disconnect the red and...

Страница 13: ...shaft dimensions Pool width 596 mm Beam width Pool width 636 mm Overall dimensions Pool width 910 mm 140 3 10 Final overall dimensions of the OPEN SURF2 slatted cover Pool length 8 m 10 m 12 m D min d...

Страница 14: ...connecting cable to the terminals marked and in the box Fig 32 230V AC 24V DC ON OFF T N P 2A 4 1 2 Connect the power cables to the screw terminal inside the stand Fig 33 Test the tube s rotation in...

Страница 15: ...32 Connect the 230 V power supply cable in the electric box to the terminal marked T for the earth P for the phase and N for the neutral Connect the two power wires of the connecting cable to the term...

Страница 16: ...cabled solar model electric diagram SURF System 1 Connect the spiral wire to the screw terminal inside the previously installed solar stand SURF System 2 The solar panel is assembled on the SURF fram...

Страница 17: ...nds on wires 1 and 2 of the motor cable and not directly the box and Check the condition and the correct tightening of the electric connections 7 1 For the models with a box 7 1 1 Checking the box Che...

Страница 18: ...gulator must be returned to AS POOL for analysis Rectifier test 24 V DC Direct Current on the square rectifier the terminal is perpendicular to the other 3 terminals The terminal is diagonally opposit...

Страница 19: ...the cover making sure that the motor cable does not get entangled Lock the safety mechanisms When commissioning the roller a new adjustment of the motor limit switches will be needed 7 3 4 Checking t...

Страница 20: ...afety mode see troubleshooting 10 1 2 The regulator emits light signals to warn the user of a change in the state of the batteries 10 2 Troubleshooting 1 2 3 Charge level Yellow LED 1 comes on at 75 Y...

Страница 21: ...be SOUTH facing West North South East Oriented towards full sunlight producing 100 of its power 11 3 Projected shade and surrounding vegetation PLEASE REMEMBER The SOLAR PANEL must not be in any SHADE...

Страница 22: ...an Open Close cycle Full batteries can power 40 cycles while leaving enough in reserve to allow a safety closure In comparison a 6 m x 12 cover that consumes an average of 3 A in 6 minutes uses 7 2 W...

Страница 23: ...Safety instructions and user guide for the automatic pool cover Please read carefully and keep available for later use 01 2022 Version AE 12 018 12EN 01 2022 Slatted covers...

Страница 24: ...hildren Drowning happens very quickly Children close to a pool require constant monitoring and active supervision even if they can swim The physical presence of a responsible adult is indispensable wh...

Страница 25: ...he sound level generated by the automatic safety cover when running is 65 dB 0 0UV FERM The cover is controlled using a control that is locked using a key or an access code placed in the immediate poo...

Страница 26: ...s complete 6 Keep a permanent view over the cover and the pool while it is moving Make sure to keep people away from the roller 7 Keep the control key or the remote control out of the reach of childre...

Страница 27: ...use brownish stains to appear on the slats This natural phenomenon is not covered by our guarantee 3 Advice for use Always check that the pool water level remains constant and in compliance with the m...

Страница 28: ...er level regulation overflow not clogged automatic filling correctly set Make sure that the area where the cover motor is located is fitted with a drain preventing the motor from being submerged at al...

Страница 29: ...on the specificities of the pool AS POOL does not communicate directly with pool owners Have the automatic cover serviced by a swimming pool professional we recommend your swimming pool installer whos...

Страница 30: ...t the batteries must be disconnected and stored in a dry place When putting back into service let the batteries charge a half day of sunlight before operating the cover 7 Guarantee Our one year guaran...

Страница 31: ...Blue PVC Light grey PVC Galet grey PVC Blue tinted two ply PVC Clear polycarbonate Blue tinted translucent polycarbonate Blue tinted two ply polycarbonate Mother of pearl tinted two ply polycarbonate...

Страница 32: ...ic box check the 10A 30mA ground fault circuit breaker The on off button on the box is ON Fuses are in good condition 12 V or 24 VDC voltage on the motor power terminals when the key is turned Continu...

Отзывы: