PROBOIL 2 to PROBOIL.2X Upgrade Installation Guide v1b 

 

OR: Continue to use the PROBOIL2 tundish and drain hose (Not preferred option) 

 

 

1.

 

Pull black rubber boiled water 
outlet pipe (E2) from tundish (E3). 
 

2.

 

Push silicone outlet tube (K) onto stem of 
tundish (E3). 

 

 

2.1.3

 

Install the new PROBOIL2X

PROBOIL2X

PROBOIL2X

PROBOIL2X replacement boiler 

 

This drawing can be used for reference throughout the PROBOIL2X replacement process: 

Key 

Description 

Drawing 

PROBOIL.2X boiler unit 

 

½” male boiler inlet (with 
internal check valve) 

3/8” male boiler outlet 

mains power cable 

¼” flexible blue inlet pipe 

¼” x ¼” inlet pushfit 
connector  

½” blue Inlet “wingnut” 
connector (with integral 
“flat” rubber seal) 

inlet connector meshed 
filter seal 

Outlet connector rubber 
seal 

3/8” red Outlet “wingnut” 
connector 

Silicone outlet tube (0.75M) 

8mm barbed stem x 3/8” 
male tap connector 

2 x Wall fixing screws 

2 x Wall fixing plugs 

½” inlet transport cap 

3/8” outlet transport cap 

3/8” female flexible 
(braided/silicone) hose tap 
connector assembly and 
fibre seal (supplied with 
tap) 

 

Содержание Pronteau PROBOIL2

Страница 1: ...www proboil co uk See top of boiler unit for contact details Please read these instructions carefully before installation We have a policy of continued product and quality development and improvement...

Страница 2: ...proboil2x boilers like for like if any modifications are to be made please refer to the complete user and installer guide supplied originally with the product WARNING All surfaces especially those mad...

Страница 3: ...place any water connections directly near or above electrical appliances or connections WARNING This appliance is not intended to be operated by means of an external time or separate remote control s...

Страница 4: ...bols are used to highlight key points or safety considerations An information point or tip for installation or usage A service maintenance or care consideration A technical or safety consideration or...

Страница 5: ...uding non return valve 1 B2 15mm olive B3 15mm nut B4 15mm pipe B5 15mm isolation valve B6 Domestic hot flexible hose excluding non return valve C1 Cold out to filter boiler flexible hose including se...

Страница 6: ...nit Drain fully into a suitable container or sink 6 Once drained close the unit and place the boiler to one side EITHER Bypass the existing Proboil 2 black tundish assembly This is the preferred optio...

Страница 7: ...cription Drawing A PROBOIL 2X boiler unit B male boiler inlet with internal check valve C 3 8 male boiler outlet D mains power cable E flexible blue inlet pipe F x inlet pushfit connector G blue Inlet...

Страница 8: ...wingnut inlet connector with integral internal flat rubber seal G hand tight do not use a spanner or overtighten on to the boiler inlet male B 3 Check that the red 3 8 x 8mm boiler outlet connector J...

Страница 9: ...be too short pipe is stretched c Not be twisted or kinked when attached creating a blockage 10 Your boiler is now plumbed to the tap and the filter plug the power cord into the mains outlet but do not...

Страница 10: ...he flushing period check all connections made during the installation carefully for leaks 2 After the flushing period is completed turn off close fully the 98 C water handle 3 Press and hold the key o...

Отзывы: