![Abloy DA460 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/abloy/da460/da460_installation-and-commissioning-manual_3438595016.webp)
16
7 Teach door open and closed position
6 Check the OPTION
OPTION
sing
le
ma
ster
co
rri
dor
fire n.c
free swing
OPTION
sing
le
ma
ster
co
rri
dor
fire n.c
free swing
OPTION
sing
le
ma
ster
co
rri
dor
fire n.c
free swing
Select "single" for a stand alone door. "Master" and "Corridor", not
yet available.
If the jumper is connected then operator requires N.C. output from
the fire detector.
If the jumper is disconnected then operator requires N.O. output from
the fire detector.
When jumper is connected the door can opened and closed manually.
When opening impulse comes, the door is opened to fully open
position and closed after adjusted hold open time.
Free swing is in operation when mode switch is in AUTO position.
Note! It is not possble to use Push&Go and free swing options at the
same time.
- Push TEACH-button to enter learning mode.
- Teach the door closed position
Yellow led blinks: close the door and push TEACH-button.
- Teach the door open position
Green led blinks: Open the door to the desired angle and
push TEACH-button.
- Yellow "TEACH CLOSED" led blinks: Close the door manually.
The operator's force requires adjustment to suit door weight. Use
lowest possible value to ensure the smooth function of safety feature.
Start the adjustment by putting the force potentiometer to middle
position (= 50%) and fine-tune it after opening speed adjustment.
Note! Important: as less force as possible
FORCE
Force
8 Operators force, opening speed and hold open time
COMMISSIONING
TEACH OPEN
POWER ON
TEACH CLOSED
TEACH