![Abloy DA460 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/abloy/da460/da460_installation-and-commissioning-manual_3438595015.webp)
15
COMMISSIONING
1 Check the free movement of the door.
2 Turn mode switch to MAN.
The mode switch is located in the head panel.
3 Plug in the mains and turn main switch on.
The main switch is located in the head panel.
4 Choose the type of the arm
The jumpers are located on the control board.
Jumper is connected
Jumper is disconnected
5 Check the DOOR
"Sealed" enables motorized closing pull before opening and final
pull when closing. Select this to ensure the proper function of the
lock when prepull and final pull are needed.
Final pull will be activated 20 - 30 mm before the doors closed
position. Final pull is activated 1 second, when door is closed position.
When hold closed jumper is selected, operator pushes the door
against the frame.
Push&Go is in operation, when mode switch is in AUTO position.
When door is pushed or pulled manually operator opens the door.
Operator opens the door to adjusted opening angle and closes the
door after 3 second hold open time.
Note! It is not possble to use Push&Go and free swing options at the
same time.
ARM
st
an
dard
sl
iding
sealed
hold closed
Push&Go
DOOR
sealed
hold closed
Push&Go
DOOR
sealed
hold closed
Push&Go
DOOR
Main switch Mode switch
All manuals and user guides at all-guides.com