background image

Abloy Oy

An ASSA ABLOY Group company

ABLOY

®

 

DA460 SWING DOOR OPERATOR

– Installation and commissioning manual

All manuals and user guides at all-guides.com

all-guides.com

Содержание DA460

Страница 1: ...Abloy Oy An ASSA ABLOY Group company ABLOY DA460 SWING DOOR OPERATOR Installation and commissioning manual All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...the door is in good mechanical condition and it opens and closes properly Ensure that entrapment between door and the surroundings is avoided Ensure that the operator is suited for installation Check...

Страница 3: ...on 6 Operation 7 Main switch and mode switch 7 Door weight 8 Installation 9 Internal connections 14 Commissioning 15 A safe door 18 External connections 19 Connection examples 21 Self diagnostic 28 Ma...

Страница 4: ...4 REVISION Following pages has been revised Page Revision 12 13 The lenght of sliding arm has increased Pictures has been updated As at 29 02 2008 All manuals and user guides at all guides com...

Страница 5: ...47 Standard arm screws 2 pcs 5 5x32 and 1 pcs M8x30 DA148 Extended arm screws 2 pcs 5 5x32 and 1 pcs M8x30 DA149 Sliding arm screws 2 pcs 5 5x50 and 1 pcs M8x30 DA150 Extension piece 10 mm M8x35 20 mm...

Страница 6: ...tput current 1 0 A The total load must not exceed 12W Potential free relay output preset to operate 2 seconds 2 A 30 VDC resistive load Features Usage for heavy density of pedestrian traffic Push Go a...

Страница 7: ...m amount for trials is 4 If this is exceeded or hold open time is end the door is closed Closing cycle If the door is obstructed in closing cycle The door is set free and 4 new trials are done to clos...

Страница 8: ...170 180 60 70 80 90 100 110 120 130 140 150 Door weight kg Door width cm Sliding arm Door width cm 50 60 70 80 90 100 110 120 130 140 150 160 170 180 60 70 80 90 100 110 120 130 140 150 Door weight kg...

Страница 9: ...nnecting the operator to mains Commissioning Testing Connecting impulse devices Preparing installation Check the proper function of the door hinges door clearance Check the proper function of the lock...

Страница 10: ...suring the installation base is level and securely fixed to a flat surface Installation measurements for standard arm and for sliding arm DA149 to the closing side installation When installing operato...

Страница 11: ...in damage Tighten the holding screw Frame depth DA147 0 150 mm DA148 150 250 mm Frame depth 9 0 Hinge line Mounting of the operator M8x22 and washer Y mm Length of extension piece 0 No extension piece...

Страница 12: ...20 115 750 740 735 Frame depth H mm Arm distance L mm Minimum door width M mm Hinge line Mounting of the operator M8x22 and washer Y mm Length of extension piece 47 10 mm DA150 01 57 20 mm DA150 02 67...

Страница 13: ...lding screw Frame depth DA149 0 50 50 100 100 150 150 200 185 205 235 270 800 820 850 885 Frame depth H mm Arm distance L mm Minimum door width M mm Hinge line Mounting of the operator M8x22 and washe...

Страница 14: ...supply the external 24 VDC min 3A supply can be connected to X1 connectors 2 and 3 Connect from DC supply back up to X1 connector 2 and GND to X1 connector 3 No battery charging or maintenance is pro...

Страница 15: ...are needed Final pull will be activated 20 30 mm before the doors closed position Final pull is activated 1 second when door is closed position When hold closed jumper is selected operator pushes the...

Страница 16: ...h is in AUTO position Note It is not possble to use Push Go and free swing options at the same time Push TEACH button to enter learning mode Teach the door closed position Yellow led blinks close the...

Страница 17: ...least 3 seconds In the programming mode green led is lit yellow led is flashing 3 times pause 3 times pause Adjust the hold open time for delayed impulse 0 60 sec Time starts when the door is in open...

Страница 18: ...old open times the distance from impulse device to door is preset 1 Adjust low speeds 2 Adjust the operator force to a low setting ensuring the safety feature activates on door moving 3 Adjust the hol...

Страница 19: ...d to re energise the operator to chosen program selector mode Safety Sensor On the opening side of the door Safety sensor is connected between terminals 1 and 4 The cable loop must have 1KOhm resistan...

Страница 20: ...resistance of the control switch and its wiring must not exceed 100 ohm when switch is closed Delayed impulse delay 1 0 seconds When the operator receives the opening impulse the lock is released imme...

Страница 21: ...When sensor detects an obstacle the operator opens the door for duration of the hold open time 1 2 3 4 5 6 7 8 1000 ohm 1 2 3 4 5 6 7 8 9 10 11 12 24 out Norm al Safety Locking GND circuit sensor im...

Страница 22: ...al Safety Locking GND circuit sensor im pulse Fire detector 12V out Delayed im pulse GND yellow white green pink blue brown 1 2 3 4 5 6 7 8 9 10 11 12 24 out Norm al Safety Locking GND circuit sensor...

Страница 23: ...ry switch 1 2 3 4 5 6 7 8 9 10 11 12 24 out Norm al Safety Locking GND circuit sensor im pulse Fire detector 12V out Delayed im pulse GND COM N O N C red black blue X2 X5 MANUAL no connection AUTO 2 1...

Страница 24: ...m al Safety Locking GND circuit sensor im pulse Fire detector 12V out Delayed im pulse GND Motor locks EL490 EL590 1 2 3 4 5 6 7 8 9 10 11 12 24 out Norm al Safety Locking GND circuit sensor im pulse...

Страница 25: ...SED C NOT USED NO C NC C 25 26 27 28 29 30 31 32 1 C O N T R O L S POWER BACKUP BACKUP WHITE YELLOW GREY RED BROWN BLUE ORANGE TURQUOISE PINK S N 1 EA420 GREEN BLACK VIOL 1 2 3 0 0 0 0 0 1 0 1 0 0 1 1...

Страница 26: ...m al Safety Locking GND circuit sensor im pulse Fire detector 12V out Delayed im pulse GND Impulse device ACTIVE DOOR PASSIVE DOOR Passive door opens after constant delay 1 0 seconds Adjust the hold o...

Страница 27: ...ng In fire door use the operator have to be connected to external battery back up 24VDC min 3A In case of fire the door closes After fire alarm one manual opening is required to re energise the operat...

Страница 28: ...in control board or in safety sensor 2 Check that cables are not damaged 1 Move obstacle from safety sensor detection area 2 Check that cables are not damaged 1 Switch main switch off for 10 seconds...

Страница 29: ...es are made Under 100 openings per day service once a year 100 500 openings per day service two times a year Over 500 openings per day service 3 4 times a year Inspections made in the service Greasing...

Страница 30: ...nel 810174 Rear damper 809820 Side damper 803520 Transformer 810057 Mode switch 809928 Main switch 807437 Position sensor 809863 DA147 DA148 DA149 Cover aluminium 410358 Cover white 410357 DA460 SPARE...

Страница 31: ...31 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 32: ...of locking solutions dedicated to satisfying end user needs for security safety and convenience Nimike P iv ys 02 2008 PRODUCT MANAGEMENT DOOR AUTOMATICS 29 02 2008 FH11 9312568 Abloy Oy Wahlforssinka...

Отзывы: