Setup via the ABL User Interface application
24
2
Connect an RJ45 data cable to the SBC of the
Controller charging station / control unit and the
computer.
y
For information on the location of the SBC
network jack, please refer to the corresponding
installation manual.
MODBUS
EN1
MODBUS
ME
TER
M
E
T
E
R
C
N
T
R
L
CONTROL
CONTROL
ME
TER
3
Open a web browser on your computer and enter
the following address:
http://169.254.1.1:8300/
.
This opens the
ABL User Interface
online appli-
cation, where you are automatically logged in with
the
Owner
role.
WARNING!
Manually setting up the network settings
If you are unable to connect to the application, check your
computer's network settings and, if necessary, adjust them as
follows:
Network
169.254.0.0
Subnet mask
255.255.0.0
Address
169.254.1.2
4
Click the
Change role
selection menu in the top
right and select the
Installer
role.
5
Click the
Products > Installation
tab, navigate to
the bottom of the screen and click the
Add prod-
ucts
button.
6
In the product filter, click on the
Product line
tab
and select the
External
option.
y
All available energy meters (
External Meters
)