GB 26 Installation and use
4.1 ELECTRONIC CONTROL (EB200)
With full buttons
Section 4
On/off button for the lighting.
Button for reducing the rate;
minimum 0
- Rate indicated on display
- Display switches off automati-
cally after 1 minute at rate 0
Indicator 0 – 1 – 2 – 3 – 4
Button for increasing the rate;
maximum 4
Button for enabling overrun.
The overrun time is 20 minutes
at each rate. The speed can still
be changed by selecting a
different rate. The display
flashes during the overrun time.
To switch off overrun, select
rate 0 with the [–] button.
too much heat being sucked out of the
space; in accordance with the standards
set for the energy label.
If you use a more powerful motor than 815
m³/h, then you should turn the motor speed
down to setting 1 (follow the steps below
to do so).
1. In position 0, press simultaneously on
- and + , for 5 seconds
2. Select a number by pressing the + or -
buttons.
1 = 60 minutes of high speed timer
2 = 7.5 minutes of high speed timer
3 = 3 minutes of high speed timer
3. To save, press - and + again, for 5 sec-
onds.
4.1.3 Grease filter indication
Grease filter indicator: “saturation” after be-
ing used for 40 hours. When the grease
filter is saturated, the decimal point will
light up on the display.
The grease filter indicator can be reset by
pressing and holding in the timer button on
the remote control for 5 seconds.
4.1.2 Motor step-down
After 7.5 minutes, the motor will automati-
cally switch from a high speed (setting 4) to
a lower speed (setting 3). This is in order to
avoid too many cubic metres of air and
Содержание innovent PSH0905WS
Страница 2: ...NL 2...
Страница 19: ...19 USER MANUAL INSTALLATION MANUAL General Extractors...
Страница 20: ...GB 20...
Страница 37: ...BEDIENUNGSANLEITUNG INSTALLATIONSANLEITUNG Abzugshauben Allgemein DE 37...
Страница 38: ...DE 38...
Страница 55: ...55 MODE D EMPLOI CONSIGNES D INSTALLATION G n ralit s Hottes aspirantes...
Страница 56: ...FR 56...