BAL.0374.0 • 2019-04-01
EN - 19
ROBO Compact W600
9 Maintenance and cleaning
9.1 Maintenance intervals
When using arc welding equipment, always observe the provisions of EN 60974-4 Inspection
and testing, as well as any national laws and regulations.
Check the following:
9.2 Wire guide
Each time the wire guide is changed (liner, PA liner), make sure to consult the product
information in the instruction leaflets provided.
NOTICE
• The specified maintenance intervals are guidance values and refer to single-shift
operation.
Several times a day
Weekly
Monthly
Clean weld spatter from the torch head. In
the case of heavy weld spatter build-up,
clean during each welding break.
• Clean the ROBO Compact W600
using an
ABICOR BINZEL
torch
cleaning station. Then spray with
ABICOR BINZEL
anti-spatter fluid.
We recommend basic cleaning
once a week. The type and
frequency of cleaning shall be
determined and established by
the operator of the welding
system.
• Check that the
connections (cable
assembly, control lead,
ground) are secure.
Tighten if necessary.
Optional wire brake
• Clean the wire brake once
or twice, depending on wire
quality.
9.5 Cleaning the wire
brake (optional version
with wire brake) on
page EN-22
Tab. 11
Maintenance and cleaning