EN - 14
BAL.0374.0 • 2019-04-01
6 Putting into operation
ROBO Compact W600
6.3 Connecting the coolant
1
Connect the coolant supply hose
and the coolant return hose
recirculator.
WARNING
Risk of burns
The cable assembly overheats if the coolant level is too low.
• Wear the correct protective gloves.
• Check the coolant level at regular intervals.
NOTICE
• Check the minimum fill level on the cooling unit.
• Ensure that the coolant supply and return hoses have been correctly installed. Coolant
supply = blue, coolant return = red.
• Do not use deionized or demineralized water as coolant or for leak and flow tests. This
may shorten your welding torch’s service life.
• For liquid-cooled welding torches, we recommend using
ABICOR BINZEL
BTC coolant.
Please consult the applicable safety data sheet.
• The cooling system must be purged of any air each time the device is commissioned and
after every cable assembly change: disconnect the coolant return hose from the coolant
recirculator and hold it over a collection receptacle. Close the opening on the coolant
return hose. Then re-open it by abruptly releasing it. Repeat until the coolant flows into the
collection receptacle continuously and without air bubbles.