BAL.0374.0 • 2019-04-01
EN - 15
ROBO Compact W600
6 Putting into operation
6.3.1 Connecting and adjusting the shielding gas volume
1
Connect the shielding gas cylinder to the wire feeder system.
2
Use the pressure reducer on the shielding gas cylinder to set the gas volume.
3
Depending on the version (Euro-ZA Panasonic
®
connector), mount the shielding gas
connector correctly.
6.3.2 Connecting the control lead
The control lead of the machine is open. The customer must connect a suitable plug. If all data
is provided, the system will be supplied ready for connection. Otherwise, choose a compatible
plug for your power source and connect it to the corresponding leads according to the terminal
diagram.
NOTICE
• The type and amount of shielding gas used depend on the welding task and the gas
nozzle geometry.
• Make all shielding gas connections gas-tight.
• To prevent the shielding gas supply from becoming clogged by impurities, the cylinder
valve must be opened briefly before connecting the cylinder. This will expel any impurities
that may be present.
Fig. 6
Connecting the control lead
Control lead 7-wire
Emerg. stop 2
Emerg. stop 3
Emerg. stop 1
Button
Button
Current sensor
Gas nozzle sensor
torch-side
machine-side
WH
BN
GN
YE
GY
BU
PK
B*
C*
A*
n.c.
n.c.
n.c.
n.c.
100.0084
* only connected in case of cable assemblies with emergency stop function