E48
Alarm for lack of wire
E49
Alarm for emergency switch
Ensure safety and trigger the
emergency off switch.
E50
Alarm for stuck-on wire/burned-on
wire
Loosen welding wire from seam.
E51
Alarm settings not supported
Operating mode not supported
Power source is in test mode.
Switch to MIG/MAG mode.
E52
Alarm for anti-collision
Drive the welding torch out of
collision or deactivate the sensor
function in setup if no safety cut-out
device is used.
E53
Alarm for external gas flow
measurement
External coolant flow sensor
Optional external sensor. Check to
ensure proper function. If no sensor is
used, deactivate the function in setup.
E99
General alarm
Perform a reset. Check the
configuration.
Alarm code
Alarm symbol
Alarm type
Possible remedial action
Tab. 17
Alarm codes