EN - 6
BAL.0111 • 2020-01-29
3 Product description
ABITIG
®
WH
*According to EN 60 974-7 the value for alternating current (AC) must be given at 70% of the
tested direct current value (DC).
Application process
Type of use
automatic
Type of voltage
DC or AC
DC polarity of the electrodes
Usually negative
Max. arc ignition and stabilization
voltage
12 kv
Voltage rating
141 V peak value
Control device rating
1 A AC / 250 V AC
Protection type of the machine-side
connections
(EN 60 529)
IP2X
Shielding gas (
DIN EN ISO 14175
)
CO
2
and mixed gas M21
Electrode
Industry standard tungsten electrodes suitable
for TIG use, preferably low-radiation
Tab. 3
General torch data (EN 60 974-7)
Type
Type of
cooling
Load
Duty
cycle
Electrode
diameter
Gas flow
Cooling
Torch inlet
pressure
ABITIG
®
WH
DC
AC*
Max.
supply
temp.
Min.
flow
min.
max.
A
A
%
mm
l/min
°C
l/min
bar
bar
220W
liquid
220
160
100
1.0 - 3.2
6 - 16
50
0.5
2.0
4.0
400W
liquid
400
280 100
1.6 - 4.8
5 - 22
50
0.5
2.0
4.0
Tab. 4
Product-specific torch data (EN 60 974-7)
Standard length (other lengths
available on request)
4 m, 5 m, 6 m
Coolant connection
Plug-in nipple, nom. diam. 5 mm
Cooling unit power
min. 800 W
Weight/meter
approx. 0.7 kg
Tab. 5
Cable assembly