EN - 8
6 Operation
Alignment jig
The measuring sleeves are torch-specific and have different threaded stems:
1
at the position of the contact tip.
2
Plug on/screw in the adjusting sleeve
at the position of the gas nozzle.
6 Operation
6.1 Quick Control
1
Remove the neck liner and the wire guide.
2
Fasten the change neck torch into the clamping device.
3
to the contact tip
The bending angle is correct if the tip of the test mandrel
and the contact tip
are centered.
6.1.1 Check the alignment.
1
Unscrew or pull out the gas nozzle and remove other torch-specific fittings.
2
at the position of the contact tip.
The bending angle is correct if the test mandrel
fits easily into the bore of the measuring sleeve
.
M8
WH 455, WH 505/505 TS, ROBO VTS 0/500 TS, ABIROB
®
W 500 TS
M6
WH 241/242, ROBO VTS 500/500 TS, ROBO VTS 290,
M10
WH 650/652
M7
WH cold wire / laser
M10x1
ABIROB
®
350 GC
Tab. 6
Adjusting sleeves
NOTE
Before inserting the torch into the alignment jig, check:
• whether the correct interface and the corresponding torch are inserted.
• whether the dust and welding spatters are removed. This might cause wear and reduced test
accuracy.
1
Test mandrel
2
Contact tip
Fig. 3
Quick Control
1
2
1
Test mandrel
2
Measuring sleeve
Fig. 4
Checking the Alignment
1
2