6 Putting into operation
6.1 Setting up the ABIPLAS
®
WELD
torch body
1
Insert the blunt end of the tungsten electrode into the back cap to a depth
of about 5 mm.
2
Screw the back cap into the torch body from above until reaching the
end stop.
3
Unscrew the back cap half a turn anti-clockwise.
1
Alignment gauge
2
Gas nozzle
3
Plasma nozzle
4
Gas diffuser
5
Insulating ring
6
Torch body
7
Centring ceramics
8
Tungsten electrode
9
Back cap
10
Long plasma nozzle
11
Long gas nozzle
12
Long alignment gauge
Fig. 3