4 Putting into operation
ABICLEANER
3.1
Technical data
*1 = ABICLEANER 800 AC, *2 = ABICLEANER 1000 AC/DC
4 Putting into operation
Carry out all steps in the specified sequence.
4.1
Mounting the carbon fibre brush, Fig. 3
1
Remove the screw sleeve and push the insulating sleeve underneath
and back.
2
Fasten carbon fibre brush with two open-end spanners. Counter the
adapter to prevent damage to the handle.
3
Push the insulating sleeve fully forward over the spanner flat and mount
the screw sleeve.
4
Insert the high-current plug of the carbon fibre brush into the black high-
current socket until it clicks.
4.2
Connecting the earth clamp, Fig. 4
1
Attach the ground clamp to the workpiece. Ensure good contact and
a tight fit. If required, clean the point of contact beforehand.
2
Insert the high-current plug of the earth clamp into the red high-current
socket until it clicks.
5 Operation
Distilled or demineralized water and clean paper towels are also needed for
operation.
5.1
Adjusting the length of the carbon fibre tips, Fig. 5
1
Turn the screw sleeve until 10 mm of the carbon fibre tips protrude from
the screw sleeve.
2
The carbon fibre tips wear out during operation. Readjust the screw
sleeve regularly.
5.2
Preparing the required liquids
1
Fill electrolyte from storage bottle into the wide-necked container
(approx. 15 mm). Close the storage bottle.
2
Fill distilled or demineralized water into the spray bottle.
5.3
Cleaning the weld seam
1
Plug in the mains plug and switch on the device at the main switch. The
green indicator light illuminates.
2
Set the function switch to <Cleaning> (ABICLEANER 1000 AC/DC only).
3
Briefly dip the carbon fibre brush into the electrolyte and allow excess
electrolyte to drip off.
4
Place the carbon fibre brush vertically on the weld seam. Brush over the
workpiece several times with light pressure and circular movements until
the weld seam is completely cleaned. Rinse the cleaned surface
immediately with water from the spray bottle.
5
Dip the carbon fibre brush in electrolyte at regular intervals, move back
and forth two to three times, and press the fibres on the bottom of the
wide-mouth container. This removes dissolved oxides and cools the
electrode.
6
Dry the workpiece with clean paper towels.
5.4
Polishing the weld seam (ABICLEANER 1000 AC/DC only)
1
Plug in the mains plug and switch on the device at the main switch.
The green indicator light illuminates.
2
Set the function switch to <polishing>.
3
Carry out the polishing process in the same way as the cleaning process.
The polishing process takes longer than the cleaning process. Therefore,
rinse the workpiece with water in between to avoid overheating.
4
Dry the workpiece with clean paper towels.
5.5
Completing the cleaning and polishing process
1
Carefully wipe off excess electrolyte on the carbon fibre brush at the
edge of the wide-neck container and close the wide-neck container.
Permitted ambient temperature
+5°C to +55°C
Mains voltage (depending on
type, see nameplate)
120 V / 60 Hz
230 V / 50 Hz
Power
800 VA *1
1000 VA *2
Secondary voltage
8.7 V AC *1
9.8 V AC / 12 V DC *2
IP protection type
IP 43 *1
IP 21 *2
Dimensions (LxWxH)
220 mm × 150 mm × 250 mm *1
320 mm × 150 mm × 250 mm *2
Weight
4.9 kg *1, 7.5 kg *2
Total weight with accessories
11.5 kg *1, 14 kg *2
WARNING
Risk of burns from hot surface
The workpiece becomes very hot during the cleaning/polishing process.
► Do not touch the surface. Wear the correct protective gloves.
► Cool the workpiece by rinsing it.
WARNING
Risk of burns from hot surface
The workpiece becomes very hot during the cleaning/polishing process.
► Do not touch the surface. Wear the correct protective gloves.
► Cool the workpiece by rinsing it.