EN - 6
3 Putting into operation
AB Series Torches
3 Putting into operation
3.1 Equipping the torch
3.1.1 Equipping
spare parts onto the torch neck
Equip the torch neck according to the following figure:
3.1.2 Changing the torch neck or adjusting the torch neck´s direction
1
Uncover the black cover cap on the handle.
2
Loosen the torch neck lock bolt with an inner hexagonal wrench (4 mm), but
do not unscrew the bolt out.
3
Pull out the torch neck, insert the new torch neck in and turn it to the correct
position.
4
Fasten the lock bolt and cover the cover cap again.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Close off the gas supply.
• Disconnect all electrical connections.
CAUTION
Risk of injury
Piercing or puncture caused by electrode tip.
• Do not reach into the danger zone and wear protective gloves.
1
Gas nozzle
2
Contact tip
3
Gas diffuser
4
Nozzle holder
5
Torch neck