ABBRA INSTALLATION GUIDE Version.04 4/12/17
19
4.6.4 GSM Line Failure Reporting
Here you determine whether GSM network failure will be
reported after 2 min., after 5 minutes, after 15 min., or after
30 minutes.
Available options:
don't report
,
2 min
,
5 min
,
15 min
, or
30 min
.
4.6.5 GSM Line Purpose
Define whether the GSM unit will serve as a backup for the
regular telephone line, as a primary communication
channel or as the only telephone channel or for sending
SMS only.
Available options are:
GSM is backup, GSM is primary
or
GSM only
or
SMS only
.
4.7 DEFINING OUTPUT PARAMETERS
4.7.1 Preliminary Guidance
This mode allows you:
a. Events/conditions selection under which the PGM
(programmable) output and fifteen “X-10” devices will
function.
b. Function type selection for every X-10 unit and for PGM
output.
c. General definitions selection for X-10 units
d. Selection of the internal siren or STROBE light (that will
be activated according to system programming).
e. Enrolling 2-way X-10 units.
The process is shown in Fig. 4.7. Each selected option is
displayed with a dark box at the right side. To review the
options, repeatedly press <Next> or <Back> button, until
the desired option is displayed, then press <View/Select>
button.
4.7.2 Define PGM
For the PGM output, you can select
disable, turn on
,
turn
off
or
pulse active
(turn on for predefined period, selected
by
PULSE TIME
), as follows:
n
BY ARM AWAY (
upon AWAY arming).
n
BY ARM HOME
(upon HOME arming).
n
BY DISARM
(upon disarming).
n
BY MEMORY
(activated upon registration of an alarm in
the memory, turned off upon memory clearing).
n
BY DELAY
(during exit / entry delays).
n
BY KEYFOB
(upon AUX button pressing in the keyfob
transmitter / MCM-140+, if “
PGM/X-10
” is selected in
“Define Panel” menu, location 17).
n
BY ZONES
(by disturbance in each of 3 selected zones,
irrespective of arming / disarming). If you select
toggle
,
the PGM output will be turned on upon event occurrence
in these zones and will be turned off upon next event
occurrence, alternately.
n
BY LINE FAIL:
PGM output is ON if telephone line is
disconnected.
4.7.3 Defining INT/STRB
Here you determine if the INT output will be used for an
internal siren
or for a
strobe
.
4.7.4 X-10 GENERAL DEF
(Not evaluated by UL)
For X-10 devices, you can select the following actions:
n
FLASH ON ALARM
(you can select
no flash
or
all light
flash
, to control X-10 lighting devices in alarm
conditions).
n
TRBL INDICATION
(you can select
don't indicate
or
indicate
for X-10 failure indication by the TROUBLE
LED).
n
FAIL REPORT
(You can select
report to central
station 1
,
report to central station 2, report to pager,
report to private telephone
and
send SMS
, for X-10
devices failure reporting).
n
3 PHASES & FREQ
(you can select
disable 3 phase
,
3
phase 50 Hz
, or
3 phase 60 Hz
to define the X-10
signal transmission type).
n
LOCKOUT TIME
(You can enter daytime limits between
which X-10 lighting devices controlled by sensors will be
off, even when the associated sensors are triggered).
In UL installations, this function shall not be used.
4.7.5 X-10 UNIT DEFINE
(Not evaluated by UL)
For the fifteen X-10 units you can perform the following
programming actions:
a. House code selection (a code letter from A to P that will
distinguish the site in which the system is installed from
other sites in the neighborhood).
b. Specific number definition for every X-10 unit (01 – 15).
c. Enrolling 1-way X-10 units
d. Enrolling 2-way X-10 units (that can perform status reporting).
Note:
If a 2-way X-10 unit is installed without enrolling,
interference to the 1-way X-10 units operation may
occur.
e. For each X-10 unit you can select
disable, turn on
,
turn
off
or
pulse active
(turn on for predefined period,
selected by
PULSE TIME
), upon the following
conditions:
n
BY ARM AWAY (
upon AWAY arming).
n
BY ARM HOME
(upon HOME arming).
n
BY DISARM
(upon disarming).
n
BY MEMORY
(activated upon registration of an alarm
in the memory, turned off upon memory clearing).
n
BY DELAY
(during exit / entry delays).
n
BY KEYFOB
(upon AUX button pressing in the
keyfob transmitter / MCM-140+, if “
PGM/X-10
” is
selected in “Define Panel” menu, location 17).
n
BY ZONES
(by disturbance in each of 3 selected
zones, irrespective of arming / disarming). If you
select
toggle
, the PGM output will be turned on upon
event occurrence in these zones and will be turned off
upon next event occurrence, alternately.