ABBRA INSTALLATION GUIDE Version.04 4/12/17
11
4.2.4 Enroll/Delete Keyfob Transmitters
(Not evaluated by UL).
Keyfob transmitters are multi-button wireless CodeSecure™
transmitters. Eight system users use them for better,
quicker and safer control over various system functions.
Note:
For UL installations, if MCT-234 keyfob is used
the Abbra voice/speaker shall be enabled.
To enroll / delete keyfob transmitters, refer to figure 4.2.
4.2.5 Enroll/Delete Wireless Commander
(Not evaluated by UL).
The Wireless commander is a remote control unit that
enables the user to remotely control the system. To enroll /
delete up to 8 wireless commanders, refer to figure 4.2
(Enroll WL 1-way KP).
4.2.6 Enroll/Delete 2-Way Keypad
The 2-way keypad, type MKP-150, enables the user to
remotely control the system and also to receive data from
the system (status, alarm and trouble data). To enroll up to
two 2-way keypads, refer to figure 4.2.
4.2.7 Enroll/Delete Wireless Siren
The wireless siren is a remote siren that is activated upon
predefined events by the Abbra system. To enroll / delete
up to 2 wireless sirens, refer to figure 4.2.
4.3 DEFINING ZONE TYPES, NAMES & CHIME ZONES
This mode allows you to assign one of 12 zone types to
each of the system's 30 (wireless & wired) zones. In
addition, it also allows you to assign a name to each zone
and determine whether the zone will operate as a chime
zone (only while the system is in the disarmed or Home
arming state). When a chime zone is triggered, chime
melody or zone name is heard (there are 3 selectable
chime modes - Melody chime, Zone Name Chime or
Chime Off).
A list of factory defaults is printed on table 1. You may fill
out the blank columns even before you start and proceed
to program according to your own list.
Remember!
A delay zone is also a perimeter zone by definition.
Zone types are fully explained in Appendix D.
For UL installations, hard wired zones are not intended
to be used as FIRE zones.
Selectable Zone Names
Dining room
Downstairs
Emergency
Fire
Front door
Garage
Garage door
Guest room
Hall
Kitchen
Laundry room
Lving room
Master bath
Master bdrm
Office
Upstairs
Utility room
Yard
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet
Den
31 zone names can be selected, 26 fixed names and 5
custom names (defined by the installer - see chap. 4.8):
Zxx: CHIME
Zone name-chime
(**)
OK
OK
ZONE No
: - -
Zxx: TYPE -
[Zone No.] (e.g. 05)
OK
NEXT
1. Inter-follow
2. Perimeter
OK
Melody-chime
Chime off
Zxx: NAME - -
NEXT
OK
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet
OK
OK
OK
(*)
(*)
(*)
4. Delay 1
5. Delay 2
6. 24h silent
7. 24h audible
8. Fire
9. Non-alarm
10. Emergency
3. Perim-follow
(see list above)
OK
OK
OK
11. Gas
12. Flood
13. Interior
(First display is READY
or NOT READY)
3. DEFINE ZONES
READY 00:00
NORMAL MODE
NEXT
[installer code]
<OK> TO EXIT
USER SETTINGS
ENTER CODE
2.
ENROLLING
5.
DEFINE COMM
NEXT
9. DIAGNOSTICS
NEXT
INSTALLER MODE
6.
DEFINE GSM
7.
DEFINE OUTPUTS
NEXT
8. RECORD SPEECH
10. USER SETTINGS
11. FACTORY DEFLT
12. SERIAL NUMBER
13. START UL/DL
NEX
T
NEX
T
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
OK
NEXT
NEXT
NEXT
Figure 4.3 - DEFINE ZONES Flow Chart
* The currently saved option is displayed with a dark box at the right side. To review the options, repeatedly press <
Next
Item
> or <
Back
> button, until the desired option is displayed, then press <
View/Select
> (a dark box will be displayed at
the right side).
** Pressing the <
View/Select
> button in this location brings you to the same zone number that you are dealing with. Press
<
Next Item
> or <
Back
> to select the next zone.