![ABB VD4 Series Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/abb/vd4-series/vd4-series_product-manual_3426151030.webp)
30
-X0
A
7
A
16
A1
A5
B15
C
15
A10
C
3
C
5
B
4
A
12
B2
B5
B1
1
B
7
A
15
B9
B13
D
15
D7
D5
C7
C14
D
2
-K0
1
4
2
7
-X
92
4
1
-S1
22
21
53
54
32
31
13
14
-S7
1
2
-S8
53
54
43
44
33
34
23
24
13
14
-M0
M
-S3
21
22
31
32
53
54
13
14
43
44
-S4
13
14
53
54
41
42
31
32
21
22
-S5
13
14
43
44
53
54
31
32
21
22
8
-X
35
6
41
42
-Y7
-Y1
-S2
0
2
-R0
-X
17
12
13
-S9
53
54
43
44
33
34
23
24
13
14
-Y0
-Y3
-K0
A
B
-Y9
-Y4
-Y2
18
-X
1
1
14
15
16
-X0
A
8
A
9
A
2
D
13
D14
C
8
A
6
B
16
C2
C1
A1
1
C
4
C
6
A
4
A
3
A
14
A13
B
3
B
6
B
8
B
1
B
10
B14
D
16
D8
D6
D12
D
4
D
3
D
1
C
16
-Q0
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
-Q0
OFF
ON
A
E
-V1
-V0
-V3
-V9
-V4
-V2
P
+
-
~
~
~
~
+
-
+
-
~
~~
~
+
-
--
+
+
~
~
~
~
Mode of presentation:
•
Aux. switch -S1 shown for c.b.-mechanism discharged
•
C
.b.-unit in service position
•
Control wiring plug 64-pole
•
Earthing switch mechanical interlock with c.b.-unit:
a)
C.b.-unit in test position:
Earth. switch can be operated
b)
Earth. switch open position:
C.b.-unit can be moved in the service position
-Y0
B
lock magnet on truck with rectifier -V0
-Y1
Closing block magnet with rectifier -V1
-Y2
1. Shunt release OFF with rectifier -V2
-Y3
Closing release with rectifier -V3
-Y4
Undervoltage release U< with rectifier -V4
-Y7
Indirect overcurrent release
-Y9
2. Shunt release OFF with rectifier -V9
-M0 Charging
motor
-K0 Antipumping
relay
-S1
Auxiliary switch on mechanism
-S2
Auxiliary switch on block magnet -Y1
-S3
Auxiliary switch on switch shaft
-S4
Auxiliary switch on switch shaft
-S5
Auxiliary switch on switch shaft
-S7
Fleeting contact 35ms for c.b. tripped indication
-S8
Limit switch test position
-S9
Limit switch service position
SER
VICE-
POSITION
TEST
-
POSITION
Figure 3/12:
Wiring diagram for VD4 vacuum circuit-breaker on manually movable withdrawable assembly.
• Type B of withdrawable part
• Maximum of equipment
• With closing block magnet -Y1
• Auxiliary switch -S5 wired
• Control wiring plug 64-pole
• Use in panel system ZS8.4
• Drawing no. GCE5589251S0101