Assembly Instructions / TPR56FV.. - TPR61FV..
5 Storage of new turbochargers and spare parts /
© Copyright 2018 ABB. All rights reserved.
HZTL455311P0033_EN
Revision B
May 2018
5
Storage of new turbochargers and
spare parts
Storage of new turbochargers and spare parts for up to 6 months
New turbochargers and spare parts can be stored in their closed packages for 6 months
from the date of delivery without additional mothballing measures, indicated by the VCI la-
bel on the package.
Fig. 5:
V
olatile
C
orrosion
I
nhibitor (VCI)
Only dry rooms with 40...70 % atmospheric humidity, in which no water condensation can
form, are suitable as storage locations.
Storage of new turbochargers and spare parts for more than 6 months
WARNING
Health protection when handling VCI
VCI products are not hazardous in terms of the Ordinance on Hazardous
Substances. Nevertheless, the following points must be observed when
handling VCI:
u
Observe information in material safety data sheet
u
Ensure proper space ventilation.
u
Do not eat, drink or store food at the workplace while working with VCI.
u
Clean hands and face after working with VCI.
u
For more information, see
.
Wear safety gloves to protect against mechanical hazards.
Every 6 months, the following mothballing measures are required:
u
Open package.
u
Remove VCI corrosion protection emitter from package and replace with a new VCI corro-
sion protection emitter of the same kind. New VCI corrosion protection emitters can be
obtained from
.
u
Old VCI corrosion protection emitters must be disposed of in an environmentally compat-
ible, professional way and in compliance with locally applicable regulations.
u
Close package. The more tightly the package is sealed, the longer the protection dura-
tion.