16
Normal status, display off
Current on phase L1
Current on phase L2
Current on phase L3
Neutral current Io
Maximum demand current
value for 15 minutes
4
Second setting
value for t> or k
Actual operate time t> or
multiplier k for stage I>
2
1
Second setting
value for I>>
Actual start value I>>
2
1
Second setting
value for t>>
Actual operate time t>>
of stage I>>
2
1
Second setting
value for Io>
Actual start value Io>
2
1
Second setting
value for to> or ko
Actual operate time to>
or multiplier ko
2
1
Second setting
value for Io>>
Actual start value Io>>
2
1
Second setting
value for to>>
Actual operate time to>>
2
1
Main setting of
SGF1 checksum
Actual setting of functional
switchgroup SGF1
2
1
Actual setting of blocking
switchgroup SGB
1
Main setting of
SGB checksum
Actual setting of relay
switchgroup SGR1
1
Main setting of
SGR1 checksum
2
Event (n-1)
value of phase L1
Event (n-2)
value of phase L1
Latest memorized, event (n)
value of phase L1
1
1
2
Event (n-1)
value of phase L2
Event (n-2)
value of phase L2
Latest memorized, event (n)
value of phase L2
2
1
2
Event (n-1)
value of phase L3
Event (n-2)
value of phase L3
Latest memorized, event (n)
value of phase L3
3
1
2
5
Duration of event (n-1)
starting of stage I>
Duration of event (n-2)
starting of stage I>
1
2
6
1
2
Duration of event (n-1)
starting of stage I>>
Duration of event (n-2)
starting of stage I>>
Latest memorized, event (n)
value of neutral current Io
7
Event (n-1)
value of current Io
Event (n-2)
value of current Io
1
2
8
1
2
Duration of event (n-1)
starting of stage Io>
Duration of event (n-2)
starting of stage Io>
9
Duration of event (n-1)
starting of stage Io>>
Duration of event (n-2)
starting of stage Io>>
2
1
Status of external relay
blocking / control signal
0
Communication rate
setting [Bd]
Loss of bus traffic time
counter 0..255 s
Relay unit identification
address for communication
A
1
2
Main setting
value for t> or k
Main setting
value for I>>
Main setting
value for t>>
Main setting
value for Io>
Main setting
value for to> or ko
Main setting
value for Io>>
Main setting
value for to>>
Second setting of
SGB checksum
2
Second setting
value for I>
2
1
Main setting
value for I>
Actual start value I>
0
000
I>
I>&t>
I»
I»&t»
Io>
Io>&to>
Io»
Io»&to»
Duration of event (n)
starting of stage I>
Duration of event (n)
starting of stage I>>
Duration of event (n)
starting of stage Io>
Duration of event (n)
starting of stage Io>>
SUBMENUS
FWD. STEP 1 s
REV. STEP 0.5 s
M
A
I
N
M
E
N
U
R
E
V.
S
T
E
P
.5
s
F
W
D.
S
T
E
P
1
s
1
2
3
5
6
7
8
9
A
MAIN MENU
SUBMENUS
STEP 0.5 s PROGRAM 1 s
Highest maximum
demand value found
1
Main setting of
SGF2 checksum
Main setting of
SGR2 checksum
Menu and
register chart