Commissioning of the KNX function via ABB DCA SmartTouch 10 (from
ETS5)
Product manual 2CKA001473B5343
│
85
Proximity sensor
■
Use approximation for switching on the display
Options: Activated
Deactivated
When the checkbox is activated, a proximity is used as switch-on criteria for the display.
■
Sensitivity of the proximity function
Options: 1
2
3
The parameter us used to specify the sensitivity of the proximity function (1 = near, 3 = max.
distance).
Notice
The parameter is only available if the parameter "Use approximation to switch on
the display" is activated.
■
Use 1-bit output object of proximity function
Options: Activated
Deactivated
When the checkbox is activated, a 1-bit output object of the proximity function is used.
Notice
The parameter is only available if the parameter "Use approximation to switch on
the display" is activated.
■
Switch-on value
Options: Off
On
The parameter is used to set the switch-on value of the proximity sensor.
Notice
The parameter is only available if the parameter "Use approximation to switch on
the display" and the "Use 1-bit output object of proximity function" are activated.
Содержание SmartTouch B/stainless
Страница 57: ...Commissioning via ABB free home Product manual 2CKA001473B5343 57 ...
Страница 59: ...Commissioning via ABB free home Product manual 2CKA001473B5343 59 Abb 33 Other settings Part 2 ...
Страница 84: ...Commissioning of the KNX function via ABB DCA SmartTouch 10 from ETS5 Product manual 2CKA001473B5343 84 ...
Страница 121: ...KNX control elements and application parameters Switch control element Product manual 2CKA001473B5343 121 ...
Страница 302: ...KNX communication objects Application Internal RTC Product manual 2CKA001473B5343 302 Pa ...
Страница 309: ...Operation Product manual 2CKA001473B5343 309 12 2 2 Additional basic principles Fig 46 Basic principles ...