Status LEDs at power-up
The system performs a test of the MS and NS LEDs during startup. The purpose
of this test is to check that all LEDs are working properly. The test runs as follows:
LED action
Order
NS LED is switched Off.
1
MS LED is switched On green for approx. 0.25 seconds.
2
MS LED is switched On red for approx. 0.25 seconds.
3
MS LED is switched On green.
4
NS LED is switched On green for approx. 0.25 seconds.
5
NS LED is switched On red for approx. 0.25 seconds.
6
NS LED is switched On green.
7
Reset button
The DSQC1042 safety digital base device has a reset button located under the
status LEDs. The reset button can be used in different ways to reset the device.
Indication
Description
Function
Regular reset, same as tog-
gling the power.
Pressed once (<3 sec)
The Power LED flashes red
once.
Resets the IP-settings to ABB
default values.
Short press and hold (>3 sec)
The Power LED flashes red
two times.
Factory reset.
Long press and hold (>10
sec)
CAUTION
Use a straightened out paper clip or a similar blunt object to carefully press the
reset button. Using sharp objects or pressing with force may damage the reset
button.
Note
Factory reset can also be made remotely via RobotStudio, see
resetting an I/O device configuration on page 66
Application manual - Scalable I/O
29
3HAC070208-001 Revision: F
© Copyright 2019-2022 ABB. All rights reserved.
2 Hardware overview
2.2.2 Safety digital base device, DSQC1042
Continued
Содержание RobotWare 7.7
Страница 1: ...ROBOTICS Application manual Scalable I O ...
Страница 2: ...Trace back information Workspace 22B version a10 Checked in 2022 06 15 Skribenta version 5 5 019 ...
Страница 6: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 54: ...This page is intentionally left blank ...
Страница 80: ......
Страница 81: ......