manual and auto modes. The relay’s LHMI works as the local
operator interface for controlling the autosynchronizing
sequence. An external injection device (REK 510) enables the
generator’s excitation circuit supervision against earth faults.
Best match for current and voltage measurement needs can be
managed by selecting both AIM1 and AIM2 cards for the relay.
This combination offers 11 current and 9 voltage channels to be
freely allocated to the functionalities in the relay. The
generator’s stator winding temperatures are monitored using
RTD sensors.
IEC 61850-8-1 / -9-2
Bus A
Bus B
1) Receiving two 9-2 streams
2) Receiving one 9-2 streams and sending one
3) Point-to-point protection communication channel
1)
2)
2)
1)
1)
3)
3I
RTD
REX640
SIM1 + AIM1 + RTD1
3I
6CT + 6VT + 3 combi
sensors
LHMI
10RTD + 2mA
Base Functionality
APP8
Transf. Prot.
APP10
Transf. AVR
REX640
SIM1
3I
1CT + 1VT + 3 combi
sensors
LHMI
Base Functionality
APP1
EF prot. ext.
APP2
Fault locator
REX640
SIM1
3I
1CT + 1VT + 3 combi
sensors
LHMI
Base Functionality
APP1
EF prot. ext.
APP2
Fault locator
APP4
Line diff.
3I
RTD
REX640
SIM1 + AIM1 + RTD1
3I
6CT + 6VT + 3 combi
sensors
LHMI
10RTD + 2mA
Base Functionality
APP8
Transf. Prot.
APP10
Transf. AVR
3U
3U
3I
3U
REX640
SIM1
1CT + 1VT + 3 combi
sensors
Base Functionality
LHMI
3U
Io
Io
GUID-4205F769-320E-42B1-8206-1F266F73D4FC V1 EN
Figure 14.
Digital switchgear application
REX640 is perfectly aligned with the needs of digital switchgear.
Sensors are used for the local phase current and voltage
measurements, apart from the high-voltage side current
measurement used for power transformer protection, which is
carried out by conventional current transformers. For the
outgoing cable feeders, the earth-fault protection uses core
balance current transformers. The Bus A voltage is measured
by the relay in panel +J2, whereas the Bus B voltage is
measured by the relay in panel +J3. Both relays send the
measured bus voltages to the Ethernet bus as sampled
measured values (SMV) according to IEC 61850-9-2 LE.
Depending on the type of the feeder, it receives either one or
two SMV streams. The feeders receiving two SMV streams
automatically switch between the streams based on the
position of the busbar disconnectors. All interlocking signals
between the panels use binary GOOSE messaging according to
IEC 61850-8-1. The incoming power transformer feeders
measure also the cable side voltages to enable automatic
voltage regulation (tap changer control) and synchronizing
check functionality for circuit breaker closing.
1MRS759144 A
REX640
Product version: 1
ABB
17
Содержание RELION REX640
Страница 1: ...RELION PROTECTION AND CONTROL REX640 Product Guide...
Страница 128: ...128...
Страница 129: ......
Страница 130: ......
Страница 131: ......