![ABB RELION RET670 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/abb/relion-ret670/relion-ret670_installation-and-commissioning-manual_3414632011.webp)
Full scheme distance protection, mho characteristic
ZMHPDIS..................................................................................125
Phase-to-phase faults..........................................................125
Phase-to-earth faults............................................................126
Faulty phase identification with load encroachment
FMPSPDIS ...............................................................................127
Power swing detection ZMRPSB ..............................................128
Verifying the settings............................................................129
Testing the power swing detection function ZMRPSB ........130
Testing the
tR1 timer............................................................130
Testing the block input, interaction between FDPSPDIS
Power swing logic ZMRPSL......................................................131
protection..............................................................................132
Controlling of the underreaching zone.................................133
Completing the test..............................................................133
Phase preference logic PPLPHIZ .............................................133
Completing the test..............................................................134
Current protection...........................................................................135
Instantaneous phase overcurrent protection PHPIOC .............135
Four step phase overcurrent protection OC4PTOC .................135
Verifying the settings............................................................135
Completing the test..............................................................137
Instantaneous residual overcurrent protection EFPIOC ...........137
Four step residual overcurrent protection EF4PTOC ...............138
Four step directional overcurrent protection.........................138
Four step non-directional overcurrent protection..................138
Completing the test..............................................................139
Sensitive directional residual overcurrent and power
protection SDEPSDE ................................................................139
Measuring the operate and time limit for set values.............139
Completing the test..............................................................145
Thermal overload protection, two time constants TRPTTR ......145
Checking operate and reset values......................................145
Completing the test..............................................................146
Breaker failure protection CCRBRF..........................................146
Checking the phase current operate value,
Table of contents
5
Installation and commissioning manual
Содержание RELION RET670
Страница 1: ...Relion 670 series Transformer protection RET670 Installation and commissioning manual...
Страница 2: ......
Страница 16: ...10...
Страница 24: ...18...
Страница 26: ...20...
Страница 28: ...22...
Страница 82: ...76...
Страница 88: ...82...
Страница 94: ...88...
Страница 104: ...98...
Страница 110: ...104...
Страница 210: ...204...
Страница 230: ...224...
Страница 239: ...233...