![ABB Relion 630 Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/abb/relion-630-series/relion-630-series_product-manual_3429242017.webp)
18. Technical data
Table 7. Dimensions
Description
Value
Width
220 mm
Height
177 mm (4U)
265.9 mm (6U)
Depth
249.5 mm
Weight box
6.2 kg (4U)
5.5 kg (6U)
1)
Weight LHMI
1.0 kg (4U)
1)
Without LHMI
Table 8. Power supply
Description
600PSM03
600PSM02
U
aux
nominal
100, 110, 120, 220, 240 V AC, 50 and 60 Hz
48, 60, 110, 125 V DC
110, 125, 220, 250 V DC
U
aux
variation
85...110% of U
n
(85...264 V AC)
80...120% of U
n
(38.4...150 V DC)
80...120% of U
n
(88...300 V DC)
Maximum load of auxiliary voltage supply
35 W
Ripple in the DC auxiliary voltage
Max 15% of the DC value (at frequency of 100 Hz)
Maximum interruption time in the auxiliary DC
voltage without resetting the protection relay
50 ms at U
aux
Power supply input must be protected by an
external miniature circuit breaker
For example, type S282 UC-K.
The rated maximum load of aux voltage which is given as 35 watts. Depending on the voltage
used, select a suitable MCB based on the respective current. Type S282 UC-K has a rated
current of 0.75 A at 400 V AC.
Generator Protection and Control
1MRS757583 C
REG630
Product version: 1.3
ABB
17
Содержание Relion 630 Series
Страница 1: ...RELION 630 SERIES Generator Protection and Control REG630 Product Guide...
Страница 70: ...70...