138 Technical data
Auxiliary power connection data
Voltage
230 V AC (115 V AC optional)
Frequency
50/60 Hz
Allowed electrical system
TN-S (grounded) system. If IT (ungrounded) system, contact ABB for
instructions.
Overvoltage category
(IEC 62109, IEC 60664-1)
2
Control unit (RDCU/RMIO) connection data
Analog inputs
RDCU (A43, PVS800 master control program):
one programmable
differential current input (0 mA / 4 mA … 20 mA,
R
in
= 100 ohm).
RDCU (A41, PVS800 inverter control program):
two programmable
differential current input (0 mA / 4 mA … 20 mA,
R
in
= 100 ohm) and one
programmable differential voltage input (-10 V ... +10 V,
R
in
= 200 kohm).
The analog inputs are galvanically isolated as a group.
Insulation test voltage
500 V AC, 1 min
Max. common mode voltage
between the channels
±15 V DC
Common mode rejection ratio
> 60 dB at 50 Hz
Resolution
0.025% (12 bit) for the -10 V … +10 V input. 0.5% (11 bit) for the
0…+10 V and 0…20 mA inputs.
Inaccuracy
±0.5% (Full Scale Range) at 25
°
C (77
°
F). Temperature coefficient:
±100 ppm/
°
C (±56 ppm/°F), max.
Constant voltage output
Voltage
+10 V DC, 0, -10 V DC ± 0.5% (Full Scale Range) at 25 °C (77
°
F).
Temperature coefficient: ±100 ppm/°C (±56 ppm/°F) max.
Maximum load
10 mA
Applicable potentiometer
1 kohm to 10 kohm
Auxiliary power output
Voltage
24 V DC ± 10%, short circuit proof
Maximum current
250 mA (shared between this output and optional modules installed on
the RMIO)
Analog outputs
Two programmable current outputs: 0 (4) to 20 mA,
R
L
< 700 ohm
Resolution
0.1% (10 bit)
Inaccuracy
±1% (Full Scale Range) at 25
°
C (77
°
F). Temperature coefficient:
±200 ppm/
°
C (±111 ppm/
°
F) max.
Digital inputs
RDCU (A43, PVS800 master control program):
two programmable
digital inputs (common ground: 24 V DC, -15% to +20%) and a start
interlock input. Group isolated, can be divided in two isolated groups (see
Isolation and grounding diagram
below).
RDCU (A41, PVS800 inverter control program):
one programmable
digital input (common ground: 24 V DC, -15% to +20%) and a start
interlock input. Group isolated, can be divided in two isolated groups (see
Isolation and grounding diagram
below).
Internal supply for digital inputs (+24 V DC): short-circuit proof. An
external 24 V DC supply can be used instead of the internal supply.
Содержание PVS800-57-0100kW-A
Страница 1: ...ABB solar inverters Hardware manual PVS800 57 central inverters 100 to 1000 kW ...
Страница 4: ......
Страница 22: ...20 Safety instructions ...
Страница 64: ...62 Operation principle and hardware description ...
Страница 74: ...72 Mechanical installation ...
Страница 90: ...88 Electrical installation PE PE PE ...
Страница 124: ...122 Maintenance ...
Страница 152: ...150 Dimension drawings Frame R7i 3AUA0000083128 ...
Страница 153: ...Dimension drawings 151 AC output 3AUA0000083128 ...
Страница 154: ...152 Dimension drawings 3AUA0000083128 One DC input Four DC inputs ...
Страница 155: ...Dimension drawings 153 Frame R8i R8i 2 DC inputs option 2H382 or 4 DC inputs option 4H382 3AXD50000016935 ...
Страница 156: ...154 Dimension drawings R8i 8 DC inputs option 8H382 3AXD50000016935 ...
Страница 157: ...Dimension drawings 155 R8i AC output terminals 3AXD50000016935 ...
Страница 158: ...156 Dimension drawings R8i DC terminals of units with 2 DC inputs option 2H382 3AXD50000016935 ...
Страница 159: ...Dimension drawings 157 R8i DC terminals of units with 4 DC inputs option 4H382 3AXD50000016935 ...
Страница 160: ...158 Dimension drawings R8i DC terminals of units with 8 DC inputs option 8H382 3AXD50000016935 ...
Страница 162: ...160 Dimension drawings Frame 2 R8i 2 R8i 4 DC inputs option 4H382 or 5 DC inputs option 5H382 3AXD50000015007 ...
Страница 163: ...Dimension drawings 161 2 R8i 8 DC inputs option 8H382 or 10 DC inputs option 10H382 3AXD50000015007 ...
Страница 164: ...162 Dimension drawings 2 R8i 12 DC inputs option 12H382 or 15 DC inputs option 15H382 3AXD50000015007 ...
Страница 165: ...Dimension drawings 163 2 R8i AC output terminals 3AXD50000015007 ...
Страница 170: ...168 Dimension drawings Frame 3 R8i 3 R8i 8 DC inputs option 8H382 or 10 DC inputs option 10H382 3AXD50000015006 ...
Страница 171: ...Dimension drawings 169 3 R8i 12 DC inputs option 12H382 or 15 DC inputs option 15H382 3AXD50000015006 ...
Страница 172: ...170 Dimension drawings 3 R8i 16 DC inputs option 16H382 or 20 DC inputs option 20H382 3AXD50000015006 ...
Страница 173: ...Dimension drawings 171 3 R8i AC input terminals 3AXD50000015006 ...
Страница 178: ...176 Dimension drawings ...
Страница 179: ...Further information More information about ABB products for solar applications on the Internet www abb com solar ...
Страница 180: ...Contact us www abb com solar 3AUA0000053689 Rev H EN EFFECTIVE 2014 07 09 ...